PL ACE S)

Figure 4. A6A4 Second Converter Replacement

A6A6 First Converter Replacement

Note

For location of hardware and cables referred to in this procedure, see Figure 5.

Removal

1.Remove ac line cords, IF-Display Section, and RF Section top cover.

2.Remove two screws @ to release A6A6 First Converter from A6 RF Module. Disconnect connectors @ from A6A6 First Converter.

Installation

3.Position new A6A6 First Converter in RF Module and reconnect connectors 0. Reinstall two screws 0.

4.Replace RF Section top cover. Attach IF-Display Section to RF Section. Reconnect ac line cords.

A6 9