Replacing a pass-thru module

Replacing an existing module

CAUTION: Removing the pass-thru module from a powered enclosure results in the loss of network communications between the server blade network ports and the network infrastructure.

For continued blade-server network communication and services availability before removing the module, redirect critical high-availability services or applications to use the redundant network ports.

CAUTION: Do not connect the pass-thru module until after configuration.

1.Remove and label the cables.

2.Remove the module.

3.Slide the new module fully into the interconnect bay. For more installation information, see "Installing the module (on page 9)."

4.Close the ejector lever and wait for the module to boot completely.

Replacing a pass-thru module 13