4.Close the handle (2).
Complete installation is indicated by a green Health LED. If the Health LED is amber or power is not applied to the module, see the HP BladeSystem Enclosure Setup and Installation Guide for troubleshooting information.
Accessing the pass-thru module CLI
You can access the
Accessing the pass-thru module CLI remotely
1.Access the Onboard Administrator command line using telnet, SSH, or a serial connection. For more information on how to access the Onboard Administrator CLI, see the HP BladeSystem Onboard Administrator User Guide.
2.Use the connect interconnect <bay> command to access the module. For example, if the module is located in bay 2, enter the connect interconnect 2 command.
To properly connect to the
To disable flow control after you have connected to the module:
1.Press Enter.
2.Press Ctrl + _ (Ctrl + Shift + underscore) to access the Connect Utility menu.
3.Enter C to change the port settings.
4.Enter R to change settings for the remote port.
5.Enter N to disable flow control.
After you have exited the menu, the
NOTE: If the
Installing the