Operation

13.Check that the ES indicator or display is lit, or check that the kV indicator on the isolated enclosure reads 45-55 kV. If not, see Electrical Troubleshooting on page 39 for possible problems.

15.Spray a test piece. Examine the edges for coverage. If wrap is poor, see Spray Pattern Troubleshoot- ing on page 37.

0 KV 100%

μα

HI

I

ES

O

LO ES

I ES O

ti1266a

ti1253a

14.Check the kV meter on the isolated enclosure; 45-55 kV is normal.

ti1285a

16.When you finish spraying, perform the Shutdown procedure on page 25.

24

309293J