7 Replacing Parts

This chapter describes the removal and replacement procedures for the user serviceable components in the HP Tower Server tc2110.

NOTE

The HP Server tc2110 is highly customer serviceable. All major parts are easily accessible

 

and replaceable.

 

 

Safety Information

Follow the procedures listed below to ensure safe handling of components and to prevent harm to both you and the server:

￿￿Use an anti-static wrist strap and a grounding mat, such as those included in the Electrically Conductive Field Service Grounding Kit (HP 9300-1155).

￿￿Handle accessory boards and components by the edges only. Do not touch any metal-edge connectors or any electrical components on accessory boards.

￿￿Handle accessory boards and components by the edges only. Do not touch any metal-edge connectors or any electrical components on accessory boards.

￿￿Do not wear clothing subject to static charge build-up, such as wool or synthetic materials.

WARNING Hazardous voltages are present inside the server. Always remove AC power from the processor and other associated assemblies while working inside the unit. Serious injury may result if this warning is not observed.

Service Tools Required

Service of this product may require one or more of the following tools:

￿￿Electrically Conductive Field Service Kit (P/N 9300-1155)

￿￿CE Peripheral Exerciser Disk Kit (45935-63210)

￿￿Datacomm Test Hood, 9-pin (24540-60010)

￿￿Datacomm Test Hood, 25-pin parallel (24540-60011)

￿￿1/4 inch Flat Blade Screwdriver

￿￿T-15 Torx® Screwdriver

73