PACKAGE_TYPE

Set to MULTI_NODE.

FAILOVER_POLICY, FAILBACK_POLICY

Comment out.

NODE_NAME

Specify the names for the nodes that the ASMDG MNP will run on.

AUTO_RUN

Set to YES or NO depending on whether the ASMDG MNP is to be started on cluster join or on demand.

LOCAL_LAN_FAILOVER_ALLOWED

Set by default to YES to allow cluster to switch LANs locally in the event of a failure.

NODE_FAIL_FAST_ENABLED

Set by default to NO.

RUN_SCRIPT, HALT_SCRIPT

Set to the package control script.

RUN_SCRIPT_TIMEOUT, HALT_SCRIPT_TIMEOUT

Default value is 600 seconds for a 4 node cluster. This value is suggested as an initial value. It may need to be tuned for your environment.

DEPENDENCY_NAME, DEPENDENCY_CONDITION, DEPENDENCY_LOCATION Configure a dependency on the OC MNP.

For example, for the package using CVM:

DEPENDENCY_NAMEOC-MNP-name

DEPENDENCY_CONDITIONOC-MNP-PKG=UP

DEPENDENCY_LOCATIONSAME_NODE

SERVICE_NAME

Specify a single SERVICE_NAME, corresponding to the service definition in the control script. This service invokes Toolkit script "toolkit_asmdg.sh check".

SERVICE_HALT_TIMEOUT

Default value is 300 seconds for a 4 node cluster. This value is suggested as an initial value. It may need to be tuned for your environment.

For the RAC MNP:

------------

PACKAGE_NAME

Set to any name desired for the RAC MNP.

PACKAGE_TYPE

Set to MULTI_NODE.

FAILOVER_POLICY, FAILBACK_POLICY

Comment out.

NODE_NAME

Specify the names for the nodes that the RAC MNP will run on.

AUTO_RUN

Set to YES or NO depending on whether the RAC MNP is to be started on cluster join or on demand.

LOCAL_LAN_FAILOVER_ALLOWED

Set by default to YES to allow cluster to switch LANs locally in the event of a failure.

NODE_FAIL_FAST_ENABLED

Set by default to NO.

RUN_SCRIPT, HALT_SCRIPT

Set to the package control script.

RUN_SCRIPT_TIMEOUT, HALT_SCRIPT_TIMEOUT

Default value is 600 seconds for a 4 node cluster. This value is suggested as an initial value. It may need to be tuned for your environment.

STORAGE_GROUP

If the database is stored in a CVM disk group, specify it using this parameter.

DEPENDENCY_NAME, DEPENDENCY_CONDITION, DEPENDENCY_LOCATION

Configure a dependency on the OC MNP. If CVM or CFS is used for managing the database files, and Serviceguard Disk Group (DG) MNP and Mount Point (MP) MNP are used to handle the disk group and file system mount point, add one more dependency for the corresponding DG MNP (for CVM) or MP MNP (for CFS).

For example, for a package using CVM:

DEPENDENCY_NAMEOC-MNP-name

DEPENDENCY_CONDITIONOC-MNP-PKG=UP

DEPENDENCY_LOCATIONSAME_NODE

Support for the SGeRAC Toolkit 101

Page 101
Image 101
HP Serviceguard Extension for RAC (SGeRAC) manual Set to any name desired for the RAC MNP