WARNING! Do not attempt to install a DC power supply into an NGFW Appliance. The NGFW Appliance does not contain the grounding capability for safe installation of a DC power supply. Bodily harm and damage to the system could result.

Cabling Requirements

The S1050F appliance ships with the following cables:

One AC power cable

Null modem cable for the serial console management port (DB-9 to RJ-45) shown in Figure 2-3on page 7.

Technical Specifications

The S1050F appliance has the following specifications:

Table 2-2 S1050F Appliance Hardware Specifications

Specification

Description

 

 

Dimensions

1.73 in (H) x 16.78 in (W) x 17.72 in (D)

(unpackaged)

(4.40 cm x 42.62 cm x 45.00 cm)

 

 

Weight

15.28 lbs (6.93 kg)

 

 

Power

AC: Voltage 100 – 240; Current 4 – 2 A; Frequency 50 – 60 Hz

Requirements

The appliance’s maximum power consumption is 142 W.

 

 

 

Service Provider

Temperature: 32 – 104° F (0 – 40° C) — Operating

operating

Temperature: -4 – 158° F (-20 – 80° C) — Storage

requirements

 

 

 

 

Altitude: No degradation up to 10,000 feet (3048 m)

 

 

 

Humidity: 5% to 95% (non-condensing)

 

 

External interfaces

• 1 – 1GbE copper management port

 

• 1 – RJ-45 console port

 

• 8 – 1GbE copper ports

 

• 1 external storage card drive

 

 

Installing the Appliance

To install and complete installation setup of the appliance, see Installing the NGFW Appliance” on page 21.

8 HP TippingPoint S1000 Series

Page 20
Image 20
HP TippingPoint Next Generation Firewall manual Technical Specifications, Installing the Appliance, Cabling Requirements