Model Requirements

The following topics describe the power and cabling requirements for the S3000 Series appliances.

Power Requirements” on page 12

Cabling Requirements” on page 12

Power Requirements

The S3000 Series appliances require one input of Alternating Current (AC) that must meet the following requirements:

• AC: Voltage 100V – 240V; 12 – 6 amp; 47 – 63 Hz

WARNING! Do not attempt to install a DC power supply into an NGFW Appliance. The NGFW Appliance does not contain the grounding capability for safe installation of a DC power supply. Bodily harm and damage to the system could result.

Cabling Requirements

The S3000 Series appliances ship with the following cables:

Two AC power cables, one for each hot-pluggable power supply

Null modem cable for the serial console management port (DB-9 to RJ-45) shown in Figure 3-3on page 11.

Technical Specifications

The S3000 Series appliances have the following hardware specifications:

Table 3-2 S3000 Series Appliance Hardware Specifications

Specification

Description

 

 

Dimensions

2U – 3.46 in (H) x 16.77 in (W) x 18.70 in (D)

(unpackaged)

(8.80 cm x 42.60 cm x 47.50 cm)

 

 

Weight

22.66 lbs (10.28 kg)

 

 

Power

AC: Voltage 100 – 240; Current 12 – 6 A; Frequency 47 – 63 Hz

Requirements

The appliance’s maximum power consumption is 493 W.

 

 

 

Service Provider

Temperature: 32 – 104° F (0 – 40° C) — Operating

operating

Temperature: -4 – 158° F (-20 – 80° C) — Storage

requirements

 

 

 

 

Altitude: No degradation up to 10,000 feet (3048 m)

 

 

12 HP TippingPoint S3000 Series

Page 24
Image 24
HP TippingPoint Next Generation Firewall manual Model Requirements