5 Power-On Self-Test and Error Messages

Error Message Summary

Code #

Cause / Symptom

Short message (US)

 

 

 

0310h

Floppy A: not detected (but configured in CMOS)

Flexible Disk Drive Error

 

 

 

0311h

Floppy B: not detected (but configured in CMOS)

Flexible Disk Drive Error

 

 

 

0305h

Floppy A: plugged on Floppy B: connector

Flexible Disk Drive Error

 

 

 

0306h

General failure on floppy controller

Flexible Disk Drive Error

 

 

 

0307h

Conflict on floppy disk controller

Flexible Disk Drive Error

 

 

 

0400h

CD-ROM test failure

CD-ROM Error

 

 

 

0401h

CD-ROM not detected (but configured in CMOS)

CD-ROM Error

 

 

 

0500h

General failure on HDD onboard primary ctrl

IDE Device Error

 

 

 

0501h

General failure on HDD onboard secondary ctrl

IDE Device Error

 

 

 

0510h

HDD # 0 self-test error

IDE Device # 0 Error

 

 

 

0511h

HDD # 1 self-test error

IDE Device # 1 Error

 

 

 

0512h

HDD # 2 self-test error

IDE Device # 2 Error

 

 

 

0513h

HDD # 3 self-test error

IDE Device # 3 Error

 

 

 

0520h

HDD # 0 not detected (but configured in CMOS)

IDE Device # 0 Error

 

 

 

0521h

HDD # 1 not detected (but configured in CMOS)

IDE Device # 1 Error

 

 

 

0522h

HDD # 2 not detected (but configured in CMOS)

IDE Device # 2 Error

 

 

 

0523h

HDD # 3 not detected (but configured in CMOS)

IDE Device # 3 Error

 

 

 

0530h

Found a drive on slave connector only (primary)

IDE Device Error

 

 

 

0531h

Found a drive on slave connector only (secondary)

IDE Device Error

 

 

 

0540h

Conflict on hard disk controller

IDE Device Error

 

 

 

0600h

Found less video memory than configured in CMOS

Video Memory Error

 

 

 

0700h

Found less DRAM memory than at previous boot

System Memory Error

 

 

 

0711h

Defective SIMM (module 1, bank 1)

System Memory Error

 

 

 

0712h

Defective SIMM (module 2, bank 1)

System Memory Error

 

 

 

0721h

Defective SIMM (module 1, bank 2)

System Memory Error

 

 

 

0722h

Defective SIMM (module 2, bank 2)

System Memory Error

 

 

 

95

Page 95
Image 95
HP XA 0310h, 0311h, 0305h, 0306h General failure on floppy controller, 0307h Conflict on floppy disk controller, 0401h