5 Power-On Self-Test and Error Messages

Error Message Summary

Code #

Cause / Symptom

Short message (US)

 

 

 

0731h

Defective SIMM (module 1, bank 3)

System Memory Error

 

 

 

0732h

Defective SIMM (module 2, bank 3)

System Memory Error

 

 

 

0800h

Found lower cache size than configured

System Cache Error

 

 

 

0801h

Cache self-test failure

System Cache Error

 

 

 

0900h

Lan (Chanteclerc) self-test failure

Integrated LAN Error

 

 

 

0901h

Lan (Chanteclerc) not detected (but enabled in Setup)

Integrated LAN Error

 

 

 

0A00h

Plug and Play video auto-setting failure (DDC hang)

DDC Video Error

 

 

 

The following table summarizes the most significant of the problems that can be reported.

Message

Explanation or Suggestions for Corrective Action

 

 

Operating system not found

Check whether the disk, HDD, FDD or CD-ROM disk drive is

 

connected.

 

If it is connected, check that it is detected by POST.

 

Check that your boot device is enabled on the Setup Security

 

menu.

 

If the problem persists, check that the boot device contains the

 

operating system.

 

 

Missing operating system

If you have configured HDD user parameters, check that they are

 

correct. Otherwise, use HDD type “Auto” parameters.

 

 

Resource Allocation Conflict -PCI

Clear CMOS.

device 0079 on system board

 

 

 

Video Plug and Play interrupted or

You may have powered your computer Off/On too quickly and the

failed. Re-enable in Setup and try again

computer turned off Video plug and play as a protection.

 

 

System CMOS checksum bad - run

CMOS contents have changed between 2 power-on sessions. Run

Setup

Setup for configuration.

 

 

No message, system “hangs”

Check that cache memory and main memory are correctly set in

 

their sockets.

 

 

Other

An error message may be displayed and the computer may “hang”

 

for 20 seconds and then beep. The POST is probably checking for a

 

mass storage device which it cannot find and the computer is in

 

Time-out Mode. After Time-out, run Setup to check the

 

configuration.

 

 

4 - 4 - 2 - 4

Switch 9 is not correctly set or flash is corrupted. The BIOS update

 

crisis recovery procedure is to be used.

 

 

96