MAINTENANCE

Removal of BioClip plug (Combi)

To change a Combi unit from BioClip function to cutting unit with rear ejection, remove the BioClip plug located under the unit with three screws.

1.Put the unit in the service position, see "Placing in the service position".

2.Remove the three screws holding the BioClip plug, and remove the plug.

3.Tip: Fit three full-thread screws M8x15 mm in the screw holes to protect the threads.

4.Replace the unit in normal position.

Fit the BioClip plug in the reverse order.

 

 

 

 

Service position

6017-227

 

 

 

 

 

 

Removal of BioClip plug

8009-289

English – 47