MAINTENANCE

6.Move the support wheels to their parking position.

7.Fit the front cover.

8. Secure the collet spring.

Installing BioClip 90

In order to install BioClip 90 the drive belt support wheel must first be removed.

1.Release the collet spring, see fig above.

2.Remove the locking pin (1) that is located next to the support wheel.

3.Screw off the nut and washer (2) under the centre of the support wheel. Remove the screw and support wheel.

4.Fit the cutting unit according to the instructions above.

1

2

9

Removing the cutting unit

WARNING!

Wear protective glasses when removing the cutting unit. The collet spring which tensions up the belt can go off and cause personal injury.

1.Carry out points 1-9 to put the cutting unit in the service position, see “Service position for the cutting unit”.

2.Remove the bolt (3) and lift off the cutting unit.

2

1

3

English – 29

Page 31
Image 31