MAINTENANCE

4. Useful hint: Mark the positions of the blades on the respective pulley using a felt-tip pen.

Loosen the three bolts 1/2 - 1 turn. Press the sides of the belt together to give maximum slack and tighten one of the bolts. Replace the belt and tighten as shown (see decal on cover). Set the blades at 90º to each other and loosen the bolt again. The spring ensures the correct belt tension. Check the positions of the blades again and adjust if necessary by repositioning the belt on the teeth. Tighten the three bolts to

45 Nm/32 lbft.

IMPORTANT INFORMATION

The blades on a Combi 103 unit should be set at 90 degrees to each other. In all other cases the blades can collide and cause serious damage to the cutting unit.

5. Fit the protective cover over the belts and replace the parallelism arm.

Belt change on cutting unit with rear ejection, side ejection and Combi 112

On these cutting units with “collision-proof” blades, the blades are driven by one V-belt. Do as follows to change the V-belt:

1.Remove the cutting unit.

2.Undo the bolt on the lift strut and the two screws on the cover. Lift the cover off the cutting unit.

3.Loosen the spring (4) that tensions the V-belt and pry off the belt.

Simply reverse the procedure to fit the new belt.

English – 33

Page 35
Image 35
Husqvarna 15V2 manual Maintenance