User Response: If you created the structured fields
for the form definition, either reduce the number of copy
groups in the Medium Copy Count (MCC) structured
field or reduce the number of modifications specified in
the Medium Modification Control (MMC) structured field.
Otherwise, split these functions between two or more
form environment groups in two or more medium maps.
Then, include in your input two or more identical copies
of the same page that each select an appropriate copy
group by use of the Invoke Medium Map (IMM)
structured field. Refer to
Mixed Object Document
Content Architecture Reference
for more information
about the MMC and MMO structured fields.
If you used a program to create the structured fields for
the form definition, contact your system programmer.
System Programmer Response: If an IBM licensed
program was used to create the structured fields for the
form definition with the error, verify that the input to that
program was valid. If the input was valid, refer to
Advanced Function Printing: Diagnosis Guide
for
assistance in determining the source of the problem.
APK156S DATA IN AN INPUT RECORD OR
RESOURCE IS INVALID: NULL NAME IS
NOT ACCEPTABLE IN structured field
name
STRUCTURED FIELD.
Explanation: All Begin-type and End-type structured
fields can include an 8-byte token name. A null token
name is not allowed for the listed structured field.
System Action: ACIF stops processing the print data
set. ACIF issues a message identifying the position of
the structured field in the data stream or resource.
User Response: If you created the structured fields
for the print data set or the resource, correct the error
and resubmit the print request. Refer to
Mixed Object
Document Content Architecture Reference
or
Advanced
Function Presentation: Programming Guide and Line
Data Reference
for more information about the
structured field. If the structured field has no error, the
error may be an ACIF logic error. If you used a program
to create the structured fields for the print data set or
the resource, contact your system programmer.
System Programmer Response: If an IBM licensed
program was used to create the structured fields for the
print data set or the resource with the error, verify that
the input to that program was valid. If the input was
valid, refer to
Advanced Function Printing: Diagnosis
Guide
for assistance in determining the source of the
problem.
APK157S MISMATCH BETWEEN PRINT DATA SET
AND FORMDEF RESOURCE: MEDIUM
MAP

medium map

SPECIFIED IN IMM
STRUCTURED FIELD WAS NOT FOUND
IN FORMDEF

form definition name

.
Explanation: The Token Name parameter in the
Invoke Medium Map (IMM) structured field specifies the
token name used to locate a medium map in the form
definition. This parameter must match the Token Name
parameter specified in bytes 0–7 in one of the Begin
Medium Map (BMM) structured fields in the current form
definition. The IMM structured field is contained in the
print data set.
System Action: ACIF stops processing the print data
set. ACIF issues a message identifying the position of
the structured field in the data stream or resource.
User Response: Ensure that the correct form
definition was specified. If it was, and if you added the
Invoke Medium Map structured field to the print data
set, change the Token Name in the IMM structured field
and run ACIF. Refer to
Mixed Object Document Content
Architecture Reference
for more information about the
BMM and IMM structured fields. If the correct form
definition was specified, and if you used a program to
imbed the IMM structured field in the print data set,
verify that the copy group name that you gave the
program is valid for the form definition you have
specified.
System Programmer Response: No response is
necessary.
APK158S PAGEDEF PARAMETER MUST BE
SPECIFIED IN ORDER TO PRINT THIS
DATA SET. DETERMINE THE
PERMISSIBLE VALUES USED IN YOUR
INSTALLATION FOR THE PAGEDEF
PARAMETER.
Explanation: The current data set contains at least
one record of line data. A data set containing line data
cannot be printed without an active page definition. No
PAGEDEF parameter was provided for this job.
This error can also occur if a composed-text page in the
print data set contains a structured field without the
required X'5A' control character preceding the
structured-field introducer. The missing control character
makes the record appear to be line data. A page
definition is necessary to process line data.
This error can also occur if a Presentation-Text Data
(PTX) structured field or a Begin Image (BIM) structured
field is encountered outside of a page.
System Action: ACIF stops processing the print data
set.
User Response: If you intended to print line data,
specify a page definition with the ACIF PAGEDEF
parameter.
142 ACIF User’s Guide