|duplex. This is an attempt to print the front and back
|sides of a sheet from different input bins.
|System Action: ACIF stops processing the input file.
|User Response: Correct the process used to create
|the form definition. If you used an IBM licensed program
|to create the form definition with the error, use local
|problem-reporting procedures to report this message.
|System Programmer Response: No response is
|necessary.
APK253S DATA IN A FORMDEF RESOURCE IS
INVALID: THE PRINT QUALITY VALUE
IN MMC STRUCTURED FIELD, ID
identifier
, IS NOT ACCEPTABLE.
Explanation: The Medium Modification Control (MMC)
structured field specified a print quality value of 0, which
is outside the valid range. The MMC structured field is
contained in the form definition.
System Action: ACIF stops processing the print data
set. ACIF issues a message identifying the position of
the structured field in the data stream or resource.
User Response: If you created the structured fields
for the form definition, correct the MMC structured field
and resubmit the print request. Refer to
Mixed Object
Document Content Architecture Reference
for more
information about the structured field. If the MMC has
no errors, the error may be an ACIF logic error. If you
used a program to create the structured fields for the
form definition, contact your system programmer.
System Programmer Response: If an IBM licensed
program was used to create the structured fields for the
form definition with the error, verify that the input to that
program was valid. If the input was valid, refer to
Advanced Function Printing: Diagnosis Guide
for
assistance in determining the source of the problem.
APK254S DATA IN A FORMDEF RESOURCE IS
INVALID: THE OFFSET STACKING
VALUE IN MMC STRUCTURED FIELD, ID
identifier
, IS NOT ACCEPTABLE.
Explanation: The Medium Modification Control (MMC)
structured field specified an offset stacking value other
than 0 or 1. The MMC structured field is contained in
the form definition.
System Action: ACIF stops processing the print data
set. ACIF issues a message identifying the position of
the structured field in the data stream or resource.
User Response: If you created the structured fields
for the form definition, correct the MMC structured field
and resubmit the print request. Refer to
Mixed Object
Document Content Architecture Reference
for more
information about the structured field. If the MMC has
no errors, the error may be an ACIF logic error. If you
used a program to create the structured fields for the
form definition, contact your system programmer.
System Programmer Response: If an IBM licensed
program was used to create the structured fields for the
form definition with the error, verify that the input to that
program was valid. If the input was valid, refer to
Advanced Function Printing: Diagnosis Guide
for
assistance in determining the source of the problem.
APK258S DATA IN AN INPUT RECORD OR
RESOURCE IS INVALID:
structured field
STRUCTURED FIELD IS NOT ALLOWED
BETWEEN OBJECTS.
Explanation: The structured field identified in this
message is not allowed at the point in the input data
stream or resource at which it was found.
System Action: ACIF stops processing the print data
set. ACIF issues a message identifying the position of
the structured field in the data stream or resource.
User Response: If you created the structured fields
for the print data set or resource, correct the error and
resubmit the print request. Refer to
Mixed Object
Document Content Architecture Reference
or
Advanced
Function Presentation: Programming Guide and Line
Data Reference
for more information about the
structured field. If the structured fields are in the correct
order, the error may be an ACIF logic error. If you used
a program to create the structured fields for the print
data set or resource, contact your system programmer.
System Programmer Response: If an IBM licensed
program was used to create the structured fields for the
print data set or the resource with the error, verify that
the input to that program was valid. If the input was
valid, refer to
Advanced Function Printing: Diagnosis
Guide
for assistance in determining the source of the
problem.
APK259S DATA IN AN INPUT RECORD OR
RESOURCE IS INVALID: THE
X-DIRECTION AND Y-DIRECTION
L-UNITS PER UNIT BASE VALUES
SPECIFIED IN STRUCTURED FIELD
structured field
DO NOT MATCH.
Explanation: The X-direction and Y-direction L-Units
per Unit Base values in the structured field identified in
the message are not identical.
System Action: ACIF stops processing the print data
set. ACIF issues a message identifying the position of
the structured field in the data stream or resource.
User Response: If you created the structured fields
for the print data set or the resource, correct the error
and resubmit the print request. Refer to
Mixed Object
Document Content Architecture Reference
or
Advanced
Function Presentation: Programming Guide and Line
Data Reference
for more information about the
150 ACIF User’s Guide