System Programmer Response: If an IBM licensed
program was used to create the structured fields for the
print data set or the resource with the error, verify that
the input to that program was valid. If the input was
valid, refer to
Advanced Function Printing: Diagnosis
Guide
for assistance in determining the source of the
problem.
APK118W UNSUPPORTED STRUCTURED FIELD
structured field code
WAS IGNORED, AND,
IF IT BEGAN AN OBJECT, THE OBJECT
WAS IGNORED.
Explanation: The Identifier parameter in the
structured-field introducer for the invalid structured field
specified a structured-field code that was not
recognized as a valid structured-field code.
System Action: If the structured field began an object,
the object was ignored. Otherwise, only the structured
field was ignored, and processing of the rest of the data
set continues as usual.
ACIF issues a message identifying the position of the
structured field in the input data stream or containing
resource. ACIF issues additional messages identifying
the processing environment when the error was found.
User Response: If the printed output was
unacceptable, and you created the structured fields for
the print data set or resource, give the invalid structured
field a valid code for its structured-field type. Refer to
Mixed Object Document Content Architecture Reference
or
Advanced Function Presentation: Programming
Guide and Line Data Reference
for a list of valid
structured-field types.
If the structured field has no error, the error may be an
ACIF logic error. If you used a program to create the
structured field for the print data set or resource,
contact your system programmer.
System Programmer Response: If an IBM licensed
program was used to create the structured fields for the
print data set or the resource with the error, verify that
the input to that program was valid. If the input was
valid, refer to
Advanced Function Printing: Diagnosis
Guide
for assistance in determining the source of the
problem.
APK120S DATA IN AN INPUT RECORD OR
RESOURCE IS INVALID:
structured field
name1
STRUCTURED FIELD CONTAINS
AN INCORRECT VALUE FOR THE SIZE
OF THE
structured field name2
REPEATING GROUP.
Explanation:
Structured field name1
specifies the
length of each repeating group found in
structured field
name2
. Either the value specified in
structured field
name1
for the size of the repeating group is too small,
or the actual length of the repeating-group data is not a
multiple of the size specified.
System Action: ACIF stops processing the print data
set. ACIF issues a message identifying the position of
the structured field in the data stream or resource.
User Response: If you created the structured fields
for the print data set or the resource, correct the error
and resubmit the print request. Refer to
Mixed Object
Document Content Architecture Reference
or
Advanced
Function Presentation: Programming Guide and Line
Data Reference
for more information about the
structured field. If the structured field has no error, the
error may be an ACIF logic error. If you used a program
to create the structured fields for the print data set or
the resource, contact your system programmer.
System Programmer Response: If an IBM licensed
program was used to create the structured fields for the
print data set or the resource with the error, verify that
the input to that program was valid. If the input was
valid, refer to
Advanced Function Printing: Diagnosis
Guide
for assistance in determining the source of the
problem.
APK130S DATA IN AN INPUT RECORD IS INVALID:
structured field name
STRUCTURED FIELD
IS NOT ACCEPTABLE AT THE START OF
A DATA STREAM.
Explanation: The structured-field type identified in this
message is not valid at the start of the data stream.
Subsequent error messages give additional information
about the processing environment when the error
occurred.
System Action: ACIF stops processing the print data
set.
User Response: If you created the structured fields
for the print data set, correct the error and resubmit the
print request. Refer to
Mixed Object Document Content
Architecture Reference
or
Advanced Function
Presentation: Programming Guide and Line Data
Reference
for more information about the structured
field. If the structured field has no error, the error may
be an ACIF logic error. If you used a program to create
the structured fields for the print data set, contact your
system programmer.
System Programmer Response: If an IBM licensed
program was used to create the structured fields for the
print data set with the error, verify that the input to that
program was valid. If the input was valid, refer to
Advanced Function Printing: Diagnosis Guide
for
assistance in determining the source of the problem.
138 ACIF User’s Guide