The LND and CCP structured fields are contained in the
page definition.
System Action: ACIF stops processing the print data
set, and issues a message identifying the position of the
structured field in the data stream or resource.
User Response: If you created the structured fields
for the page definition, correct the error and resubmit
the print request. Refer to
Advanced Function
Presentation: Programming Guide and Line Data
Reference
for more information about the structured
field. If the structured field has no error, the error may
be an ACIF logic error. If you used a program to create
the structured fields for the page definition, contact your
system programmer.
System Programmer Response: If an IBM licensed
program was used to create the structured fields for the
page definition with the error, verify that the input to that
program was valid. If the input was valid, refer to
Advanced Function Printing: Diagnosis Guide
for
assistance in determining the source of the problem.
APK340S DATA IN A PAGEDEF RESOURCE IS
INVALID: THE NEXT LINE DESCRIPTOR
IF CONDITIONAL PROCESSING
PARAMETER VALUE IN LND
STRUCTURED FIELD NUMBER
structured field

number

IS

value1

. THIS
EXCEEDS THE LNC STRUCTURED FIELD
COUNT VALUE OF

value2

.
Explanation: The Next Line Descriptor If Conditional
Processing parameter in the Line Descriptor (LND)
structured field has an invalid value. The value is
greater than the Count parameter in the Line Descriptor
Count (LNC) structured field in the current data map.
The LNC and LND structured fields are contained in the
page definition.
System Action: ACIF stops processing the print data
set, and issues a message identifying the position of the
structured field in the data stream or resource.
User Response: If you created the structured fields
for the page definition, correct the error and resubmit
the print request. Refer to
Advanced Function
Presentation: Programming Guide and Line Data
Reference
for more information about the structured
field. If the structured field has no error, the error may
be an ACIF logic error. If you used a program to create
the structured fields for the page definition, contact your
system programmer.
System Programmer Response: If an IBM licensed
program was used to create the structured fields for the
page definition with the error, verify that the input to that
program was valid. If the input was valid, refer to
Advanced Function Printing: Diagnosis Guide
for
assistance in determining the source of the problem.
APK341S DATA IN A PAGEDEF RESOURCE IS
INVALID: IN LND STRUCTURED FIELD
NUMBER _______, THE SHIFT-OUT
CODED FONT LOCAL IDENTIFIER WAS
NON-ZERO, BUT THE GENERATE FONT
CHANGE FLAG WAS NOT SET.
Explanation: In the Line Descriptor (LND) structured
field identified in this message, the Shift-Out Coded
Font Identifier was non-zero. The Generate Change flag
should be set to indicate that the Primary Coded Font
Local Identifier should be used whenever a shift-in code
is processed. However, the Generate Font Change flag
had a value of B'0'. The LND structured field is
contained in the page definition.
System Action: ACIF stops processing the current
data set.
User Response: Correct the process used to create
the page definition. If you used an IBM licensed
program to create the definition with the error, use local
problem-reporting procedures to report this message.
APK342S DATA IN A PAGEDEF RESOURCE IS
INVALID: THE NEXT LINE DESCRIPTOR
IF CONDITIONAL PROCESSING
PARAMETER VALUE IN LND
STRUCTURED FIELD NUMBER
structured field

number

WILL CAUSE AN
INFINITE LOOP.
Explanation: The Next Line Descriptor If Conditional
Processing parameter in the Line Descriptor (LND)
structured field caused an infinite-loop condition. The
LND structured field is contained in the page definition.
System Action: ACIF stops processing the print data
set, and issues a message identifying the position of the
structured field in the data stream or resource.
User Response: If you created the structured fields
for the page definition, correct the error and resubmit
the print request. Refer to
Advanced Function
Presentation: Programming Guide and Line Data
Reference
for more information about the structured
field. If the structured field has no error, the error may
be an ACIF logic error. If you used a program to create
the structured fields for the page definition, contact your
system programmer.
System Programmer Response: If an IBM licensed
program was used to create the structured fields for the
page definition with the error, verify that the input to that
program was valid. If the input was valid, refer to
Advanced Function Printing: Diagnosis Guide
for
assistance in determining the source of the problem.
162 ACIF User’s Guide