4 BASIC OPERATION

Checking the installation

Before turning the power ON, be sure all the connec- tions are complete. The checklist at right may be help- ful for necessary confirmation.

CAUTION: Connect the scanner unit before turning the power ON. Otherwise the magnetron inside the scanner unit might be damaged.

DChecklist

qThe 4 bolts securing the scanner unit must be firmly tightened.

wCabling must be securely attached to a mast or mounting material, and must not interfere with the rigging.

eBe sure waterproofing procedures are completed on the system cable.

rThe power connections to the battery must be of the correct polarity.

tBe sure that the plugs at the rear of the display unit have been connected correctly and securely.

(See p. 24 for details.)

Turning power ON/OFF

1

(0.25)

 

T.VECT 6M

NM CURS

000 . 0 ˚ T

0.000NM

SOG17 . 7KT

H UP

HDG253 . 4 ˚ T

IR

 

 

0.45

 

 

 

R E V

*.*

 

 

 

ROM

OK

 

 

 

RAM

OK

 

GPS

 

 

 

 

COMPASS

 

 

 

 

E B L 1

 

V R M 1

 

E B L 2

 

V R M 2

 

MOB

 

 

 

 

CURS

3 4 ˚ 3 7 . 7 2 N

1 3 5 ˚ 3 4 .4 2 E

(0.25)

 

S T B Y

T.VECT 6M

1 NM

CURS

000 . 0 ˚ T

0.000NM

SOG17 . 7KT

H UP

HDG253 . 4 ˚ T

IR

GPS

COMPASS

E B L 1

 

 

V R M 1

E B L 2

 

 

V R M 2

 

MOB

 

 

 

 

CURS

3 4 ˚ 3 7 . 7 2 N 1 3 5 ˚ 3 4 .4 2 E

qPush [POWER]/[ ] to turn the power ON.

The initial screen appears and warming up time is counted down on the screen.

The magnetron inside the scanner unit warms up for 90 sec.

[POWER]/[ ] does not function for 2 sec. after the power is turned OFF.

wWhen the countdown is completed, the Standby screen appears.

ePush [TX]/[ ] to start scanning and select the Plan Position Indicator (PPI) screen.

Targets and heading marker appear.

The screen appears approx. 2 sec. after turning the power on, when ‘AUTO’ is selected in the “TUNE” of the VIDEO menu.

rPush [POWER]/[ ] to turn the power OFF.