Icom MR-1000TTM, MR-1000RTM, EX-2714 Service MAN Menu, Service man menu, Select the language

Models: MR-1000TTM MR-1000RTM EX-2714

1 47
Download 47 pages 61.77 Kb
Page 36
Image 36

11 SERVICE MAN MENU

Service man menu

CAUTION: The SERVICE MAN MENU is available for service purposes only. DO NOT change any set- ting on the menu, otherwise the equipment may not operate at it’s original performance.

To open the “SERVICE MAN” menu.

Push [MENU]/[ ] several times to show the “SERVICE MAN” menu.

Select the language

Menu screens can be displayed in 2 different languages.

Selectable languages; ENGLISH, (CHINESE)

After opening the “SERVICE MAN” menu;

qPush [Ù] to show the present language.

wPush [Ω ≈] to select desired language, then push [Ú] to continue the setting.

e Push [MENU]/[ ] to exit the “SERVICE MAN” menu.

SERVICE MAN

 

ENGLISH

 

 

TIMING ADJ.

 

 

 

 

 

OUTPUT VOLTAGE

3 0 . 0

 

 

 

 

 

HDG ADJ.

 

 

0.0˚

HV

3 4 0

SPD ADJ.

2 4 0 0 0

 

 

MONITOR

7 5

SETUP MEMORY RECALL

HEATER

0 . 5 5

 

 

 

SAVE

MG

3 . 0

 

 

 

 

 

 

 

TX TIME

 

RANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 7 3 1 . 0 H

 

1/8

 

 

3/4

 

 

2

 

6

 

 

16

 

 

36

 

 

1/4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

3

8

 

24

 

48

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2

1.5

4

12

32

 

 

 

DTIMING ADJ.

Corrects the distance.

DHDG ADJ.

Adjusts the electronic heading line adjustment.

DSPD ADJ.

Enter the pulse rate of the speed sensor.

DRANGE

18, 14, 12, 34, 1, 1.5, 2, 3, 4, 6, 8, 12, 16, 24, 32, 36, 48* : Choose the selectable screen range.

*MR-1000TII only

DSETUP MEMORY

The present setting value is displayed by pushing [], then select the desired item from “RECALL” and “SAVE” using with [Ú].

qPush [] to display “RECALL” and “SAVE”. w Push [Ù Ú] to select “RECALL” or “SAVE”. e Push [].

“SURE ?” is displayed.

rPush [≈] to perform. t Push [Ω] to cancel.

When recall is performed without saving a setup, it will become an initial value at the time of factory shipments.

DOther readouts

OUTPUT VOLTAGE

:Shows the voltage level for the scanner unit from the display unit.

HV (High voltage) : Shows the voltage level in the high-voltage unit in the scanner unit.

• MONITOR

: Shows the voltage level for

 

checking the receiver unit opera-

 

tion.

• HEATER

: Shows the heater current.

• MG

: Shows the current level for the

 

Magnetron.

• TX TIME

: Shows the total transmitted time.

32

Page 36
Image 36
Icom MR-1000TTM, MR-1000RTM, EX-2714 instruction manual Service MAN Menu, Service man menu, Select the language