11 SERVICE MAN MENU
■Service man menu
CAUTION: The SERVICE MAN MENU is available for service purposes only. DO NOT change any set- ting on the menu, otherwise the equipment may not operate at it’s original performance.
To open the “SERVICE MAN” menu.
Push [MENU]/[ ] several times to show the “SERVICE MAN” menu.
■Select the language
Menu screens can be displayed in 2 different languages.
Selectable languages; ENGLISH, (CHINESE)
After opening the “SERVICE MAN” menu;
qPush [Ù] to show the present language.
wPush [Ω ≈] to select desired language, then push [Ú] to continue the setting.
e Push [MENU]/[ ] to exit the “SERVICE MAN” menu.
SERVICE MAN
| ENGLISH |
|
| |||||
TIMING ADJ. |
|
|
|
|
| OUTPUT VOLTAGE | 3 0 . 0 | |
|
|
|
|
| ||||
HDG ADJ. |
|
| 0.0˚ | HV | 3 4 0 | |||
SPD ADJ. | 2 4 0 0 0 |
|
| MONITOR | 7 5 | |||
SETUP MEMORY RECALL | HEATER | 0 . 5 5 | ||||||
|
|
| SAVE | MG | 3 . 0 | |||
|
|
|
|
|
|
| TX TIME |
|
RANGE |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 5 7 3 1 . 0 H | ||||
| 1/8 |
|
| 3/4 |
|
| 2 |
| 6 |
|
| 16 |
|
| 36 |
| |||
| 1/4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| 1 |
| 3 | 8 |
| 24 |
| 48 | |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| 1/2 | 1.5 | 4 | 12 | 32 |
|
|
|
DTIMING ADJ.
•Corrects the distance.
DHDG ADJ.
•Adjusts the electronic heading line adjustment.
DSPD ADJ.
•Enter the pulse rate of the speed sensor.
DRANGE
•1⁄8, 1⁄4, 1⁄2, 3⁄4, 1, 1.5, 2, 3, 4, 6, 8, 12, 16, 24, 32, 36, 48* : Choose the selectable screen range.
DSETUP MEMORY
•The present setting value is displayed by pushing [≈], then select the desired item from “RECALL” and “SAVE” using with [Ú].
qPush [≈] to display “RECALL” and “SAVE”. w Push [Ù Ú] to select “RECALL” or “SAVE”. e Push [≈].
•“SURE ?” is displayed.
rPush [≈] to perform. t Push [Ω] to cancel.
•When recall is performed without saving a setup, it will become an initial value at the time of factory shipments.
DOther readouts
•OUTPUT VOLTAGE
:Shows the voltage level for the scanner unit from the display unit.
•HV (High voltage) : Shows the voltage level in the
• MONITOR | : Shows the voltage level for |
| checking the receiver unit opera- |
| tion. |
• HEATER | : Shows the heater current. |
• MG | : Shows the current level for the |
| Magnetron. |
• TX TIME | : Shows the total transmitted time. |
32