Icom MR-1000TTM Distance and Direction Measurements, Distance measurement, Using the fixed rings

Models: MR-1000TTM MR-1000RTM EX-2714

1 47
Download 47 pages 61.77 Kb
Page 18
Image 18

5 DISTANCE AND DIRECTION MEASUREMENTS

Distance measurement

TYPE

DESCRIPTION

 

Displays fixed rings.

RING

Suitable for rough estimations from your

 

own ship to any target.

 

 

 

Displays a variable range marker and ac-

 

tivated by the [Ù Ú] for the range marker

VRM1

selector.

 

Suitable for accurate measurements from

 

your own ship to a target.

 

 

 

Normally functions the same as VRM1.

 

When the VRM1 and EBL1 selects a tar-

VRM2

get, the center of VRM2 appears at the

intersection point.

 

 

Suitable for accurate measurements from

 

target to target.

 

 

Two measurement procedures are available with this radar. Operating them separately or jointly is possible.

The distance unit, nautical miles (NM) or kilometers (KM) is selected in the FUNCTION menu (p. 6).

DUsing the fixed rings

Ring range readout

1

(0.25)

 

 

T.V E C T

NM C U R S

014 . 6˚ T

0.9 0 0 N M

SOG 0 . 0KT

H UP

HDG

IR

ES

Fixed ring

E B L 1

 

 

V R M 1

E B L 2

 

 

V R M 2

 

WPT

 

 

 

 

CURS

3 4 ˚ 3 7 . 7 2 N 1 3 5 ˚ 3 4 .4 2 E

qPush [MENU]/[ ] several times to call up the FUNCTION menu.

wPush [Ú] until the “RING” section becomes high- lighted.

ePush [≈] to select RING function ON and display the fixed ring.

The interval range appears on the right of the screen range readout.

The ring range is fixed depending on the screen range. (See below.)

rPush [MENU]/[ ] several times to exit the menu. t To clear the fixed rings, push [] to select OFF in

step e above.

Range (nm)

18

14

12

34

1

1.5

2

3

4

6

8

12

16

24

32

36

48*

Ring (nm)

120

120

110

14

14

14

12

12

1

1

2

2

4

4

8

6

8

 

2

5

5

3

4

6

4

6

4

6

4

6

4

6

4

6

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: When the screen is shifted, the number of rings may differ. *Available for the MR-1000TII only.

DUsing the variable range marker

q Push [EBL1 (VRM1)]/[ ] to display the VRM1 and EBL1; then, push [Ù Ú] to set the marker.

• The range between the ship and the target is indicated in the VRM readouts.

w Push [EBL2 (VRM2)]/[] to display the VRM2 and EBL2; then, push [Ù Ú] to set the marker.

• The range between the ship and the target is indicated in the VRM readouts.

• When the VRM1 and EBL1 are displayed, the center of VRM2 appears at the intersection point of the VRM1 and EBL1.

• The VRM2 disappears when [EBL1 (VRM1)] is pushed.

e Push [EBL1 (VRM1)]/[ ] to exit the menu display.

14

Page 18
Image 18
Icom MR-1000TTM, MR-1000RTM, EX-2714 Distance and Direction Measurements, Distance measurement, Using the fixed rings