Intel 5000 manual Thermal Calibration and Controls, IHS Groove

Models: 5000

1 52
Download 52 pages 36.15 Kb
Page 18
Image 18

 

 

 

Thermal Metrology

Table 5-1. Thermocouple Attach Support Equipment (Sheet 2 of 2)

 

 

 

 

 

 

Item

Description

Part Number

 

 

 

 

 

 

Calibration and Control

 

 

 

 

 

 

Ice Point* Cell

Omega, stable 0°C temperature source for calibration and

TRCIII

 

 

offset

 

 

 

 

 

 

Hot Point* Cell

Omega, temperature source to control and understand meter

CL950-A-110

 

 

slope gain

 

 

 

 

 

Note:

1.Three axes set consists of (1ea. U-31CF), (1ea. UX-6-6), (1ea. USM6) and (1ea. UPN-1). More information available at: http://www.narishige.co.jp/you_ltd/english/products/set/you-set.htm#3.

5.1.2Thermal Calibration and Controls

It is recommended that full and routine calibration of temperature measurement equipment be performed before attempting to perform temperature case measurement of the Intel 5000 Series chipset MCH. Intel recommends checking the meter probe set against known standards. This should be done at 0ºC (using ice bath or other stable temperature source) and at an elevated temperature, around 80ºC (using an appropriate temperature source).

Wire gauge and length also should be considered as some less expensive measurement systems are heavily impacted by impedance. There are numerous resources available throughout the industry to assist with implementation of proper controls for thermal measurements.

Note:

1.It is recommended to follow company standard procedures and wear safety items like glasses for cutting the IHS and gloves for chemical handling.

2.Ask your Intel field sales representative if you need assistance to groove and/or install a thermocouple according to the reference process.

5.1.3IHS Groove

Cut a groove in the package IHS according to the drawing given in. Figure 5-1.

18

Intel® 631xESB/632xESB I/O Controller Hub Thermal Mechanical Design Guide

Page 18
Image 18