Intel® Compute Module MFS2600KI TPS | Appendix C: POST Error Code |
The following table lists the POST error beep codes. Prior to system video initialization, the BIOS uses these beep codes to inform users on error conditions. The beep code is followed by a
Beeps | Error Message | POST Progress Code | Description |
3 | Memory error | See Table 64 | System halted because a fatal error related to the memory |
|
|
| was detected. |
|
|
|
|
1 long | Intel® TXT security | 0xAE, 0xAF | System halted because Intel® Trusted Execution |
| violation |
| Technology detected a potential violation of system |
|
|
| security. |
|
|
|
|
POST Error Beep Code
The Integrated BMC may generate beep codes upon detection of failure conditions. Beep codes are sounded each time the problem is discovered, such as on each
Code | Reason for Beep | Associated Sensors |
No CPUs installed or first CPU socket is | CPU Missing Sensor | |
| ||
| empty. |
|
|
|
|
MSID Mismatch. | MSID Mismatch Sensor. | |
|
|
|
Power fault: DC power is unexpectedly | Power unit – power unit failure | |
| lost (power good | offset. |
| dropout). |
|
|
|
|
Power control fault (power good assertion | Power unit – soft power control | |
| timeout). | failure |
|
| offset. |
|
|
|
VR Watchdog Timer sensor assertion | VR Watchdog Timer | |
|
|
|
The system does not power on or | PS Status | |
| unexpectedly |
|
| powers off and a |
|
| power supply unit |
|
| (PSU) is present |
|
| that is an |
|
| incompatible model |
|
| with one or more |
|
| other PSUs in the |
|
| system |
|
|
|
|
Revision 1.0 | Intel Confidential | 55 |