Functional Architecture

 

Intel® Compute Module MFS2600KI TPS

 

 

Table 2. Mixed Processor Configurations

 

 

 

 

 

 

Error

Severity

System Action

 

 

Processor family not

Fatal

The BIOS detects the error condition and responds as follows:

 

 

Identical

 

 

 

 

Logs the POST Error Code into the System Event Log (SEL).

 

 

 

 

 

 

 

 

Alerts the BMC to set the System Status LED to steady Amber.

 

 

 

 

Displays “0194: Processor family mismatch detected

 

 

 

 

message in the Error Manager.

 

 

 

 

Takes Fatal Error action (see above) and will not boot until the

 

 

 

 

fault condition is remedied.

 

 

 

 

 

 

 

Processor model not

Fatal

The BIOS detects the error condition and responds as follows:

 

 

Identical

 

 

 

 

Logs the POST Error Code into the System Event Log (SEL).

 

 

 

 

 

 

 

 

Alerts the BMC to set the System Status LED to steady Amber.

 

 

 

 

Displays “0196: Processor model mismatch detected

 

 

 

 

message in the Error Manager.

 

 

 

 

Takes Fatal Error action (see above) and will not boot until the

 

 

 

 

fault condition is remedied.

 

 

 

 

 

 

 

Processor cores/threads not

Fatal

The BIOS detects the error condition and responds as follows:

 

 

identical

 

 

 

 

Logs the POST Error Code into the SEL.

 

 

 

 

 

 

 

 

Alerts the BMC to set the System Status LED to steady Amber.

 

 

 

 

Displays “0191: Processor core/thread count mismatch

 

 

 

 

detected” message in the Error Manager.

 

 

 

 

Takes Fatal Error action (see above) and will not boot until the

 

 

 

 

fault condition is remedied.

 

 

 

 

 

 

 

Processor cache not

Fatal

The BIOS detects the error condition and responds as follows:

 

 

identical

 

 

 

 

Logs the POST Error Code into the SEL.

 

 

 

 

 

 

 

 

Alerts the BMC to set the System Status LED to steady Amber.

 

 

 

 

Displays “0192: Processor cache size mismatch detected

 

 

 

 

message in the Error Manager.

 

 

 

 

Takes Fatal Error action (see above) and will not boot until the

 

 

 

 

fault condition is remedied.

 

 

 

 

 

 

 

Processor frequency (speed)

Fatal

The BIOS detects the processor frequency difference, and responds

 

 

not identical

 

 

 

 

as follows:

 

 

 

 

 

 

 

 

Adjusts all processor frequencies to the highest common

 

 

 

 

frequency.

 

 

 

 

No error is generated – this is not an error condition.

 

 

 

 

Continues to boot the system successfully.

 

 

 

 

If the frequencies for all processors cannot be adjusted to be the

 

 

 

 

same, then this is an error, and the BIOS responds as follows:

 

 

 

 

Logs the POST Error Code into the SEL.

 

 

 

 

Alerts the BMC to set the System Status LED to steady Amber.

 

 

 

 

Does not disable the processor.

 

 

 

 

Displays “0197: Processor speeds unable to synchronize

 

 

 

 

message in the Error Manager.

 

 

 

 

Takes Fatal Error action (see above) and will not boot until the fault

 

 

 

 

condition is remedied.

 

 

 

 

 

 

8

Revision 1.0

 

Intel order number: G51989-002