Jumper Block Settings

 

Intel® Compute Module MFS2600KI TPS

 

 

 

Table 25. Recovery Jumpers

 

 

 

 

Jumper Name

 

Pins

What happens at system reset …

J1F3: BMC Force

 

1-2

BMC Firmware Force Update Mode – Disabled (Default)

Update

 

 

 

 

 

 

2-3

BMC Firmware Force Update Mode – Enabled

 

 

 

 

J1F4: BIOS

 

1-2

These pins should have a jumper in place for normal operation. (Default)

 

 

 

 

 

 

2-3

If these pins are jumpered, the compute module boots from the emergency BIOS

 

 

 

image. These pins should not be jumpered for normal operation.

 

 

 

 

J1F5: ME Force

 

1-2

ME Firmware Force Update Mode – Disabled (Default)

 

 

 

 

 

 

 

 

2-3

 

 

 

 

ME Firmware Force Update Mode – Enabled

 

 

 

 

J1F8: CMOS Clear

 

1-2

These pins should have a jumper in place for normal operation. (Default)

 

 

 

 

 

 

2-3

If these pins are jumpered, the CMOS settings are cleared on the next boot. These

 

 

 

pins should not be jumpered for normal operation

 

 

 

 

J1F9: Password

 

1-2

These pins should have a jumper in place for normal operation. (Default)

 

 

 

 

 

 

2-3

To clear administrator and user passwords, power on the system with pins 2-3

 

 

 

connected. The administrator and user passwords clear in 5-10

 

 

 

seconds after power on. Pins 2-3 should not be connected for

 

 

 

normal system operation..

 

 

 

 

6.1CMOS Clear and Password Clear Usage Procedure

The CMOS Clear (J1F8) and Password Clear (J1F9) recovery features are designed such that the desired operation can be achieved with minimal system downtime. The usage procedure for these two features has changed from previous generation Intel® server boards. The following procedure outlines the new usage model.

1.Power down the compute module.

2.Remove the compute module from the modular server chassis.

3.Open the compute module.

4.Move jumper from the default operating position (pins 1-2) to the Clear position (pins 2-3).

5.Wait 5 seconds.

6.Move jumper back to the default position (pins 1-2).

7.Close the compute module.

8.Reinstall the compute module in the modular server chassis.

9.Power up the compute module.

40

Revision 1.0

 

Intel order number: G51989-002