Jumpers

 

 

 

Intel® Server Board SDS2

 

 

 

 

 

CN Numbers

Qty

Manufacturer

Mfg. Part #

Functional Description

 

 

 

 

 

25

1

FOXCONN

MH11061-PD2

25-pin DSUB parallel port connector

 

 

 

 

 

22

1

FOXCONN

DT10121-P5T

DB9 serial port connector

 

 

 

 

 

33

1

FOXCONN

HL07051-P5

10-pin serial port header

 

 

 

 

 

19

1

FOXCONN

UB1112C-M1

3-pole USB connector

 

 

 

 

 

18

1

FOXCONN

HL07051-P9

10-pin USB header

 

 

 

 

 

17

1

FOXCONN

MH11061-PD2

Dual PS/2 keyboard / mouse connector

 

 

 

 

 

50

1

AMP

171825-2

2-pin chassis intrusion connector

 

 

 

 

 

1

1

MOLEX

39-28-1243

2x12-Pin ATX12 main power connector

 

 

 

 

 

10

1

MOLEX

39-28-1083

2x4-pin +12 V power connector

 

 

 

 

 

BT1

1

FOXCONN

BB10209-A5

Battery holder

 

 

 

 

 

40, 41

2

FOXCONN

HF55040

4-pin HSBP connector

 

 

 

 

 

39

1

MOLEX

22-03-5035

3-pin OEM IPMB connector

 

 

 

 

 

47

1

FOXCONN

HB11021

2-pin BMC firmware write protect header

 

 

 

 

 

46

1

FOXCONN

HB11021

2-pin BIOS write protect header

 

 

 

 

 

48

1

FOXCONN

HB11021

2-pin BMC FRB timer disable header

 

 

 

 

 

49

1

FOXCONN

HB11021

2-pin BMC FRC update header

 

 

 

 

 

5

1

SPEED TECH*

H111-1180-031

3-pin BMC SRAM header

 

 

 

 

 

8

1

FOXCONN

HB11031

3-pin CPU ITP TDO header

 

 

 

 

 

2, 20, 21, 29, 36, 38

6

FOXCONN

HF08030-P1

3-pin fan connector

 

 

 

 

 

44

1

AMP

640456-4

4-pin drive activity connector

 

 

 

 

 

6

1

MOLEX

70541-0004

5-pin AUX power connector

 

 

 

 

 

59

1

SPEED TECH

H112-1180-121

2x6-pin processor speed ratio header

 

 

 

 

 

37

1

SPEED TECH

H112-1180-121

2x17-pin front panel connector

 

 

 

 

 

42

1

FOXCONN

HC11051

2x5-pin system configuration setting header

 

 

 

 

 

J2

1

MOLEX

 

5-pin ICMB connector

 

 

 

 

 

23

1

 

 

1x8-pin cPLD Programming Header

 

 

 

 

 

9.Jumpers

9.1System Configuration Jumpers

This section describes jumper options on the Server Board.

Jumper headers provide various configuration options, as shown in the figure below. All jumper headers except the Chassis Intrusion header (CN50) are located near the front of the board, between the coin-cell battery socket and the IDE connector. The Chassis Intrusion header is located near the back corner of the board, next to the PCI Slot 6 connector.

88

Revision 1.2

Order Number:

A85874-002

Page 102
Image 102
Intel manual System Configuration Jumpers, Jumpers Intel Server Board SDS2