UPI-C42/UPI-L42

AC CHARACTERISTICS

TA e 0§C to a70§C, VSS e 0V, VCC e VDD e a5V g10%; a3.3V g10% for the UPI-L42

NOTE:

All AC Characteristics apply to both the UPI-C42 and UPI-L42

DBB READ

Symbol

Parameter

Min

Max

Units

 

 

 

 

 

 

tAR

CS, A0 Setup to RDv

0

 

ns

tRA

CS, A0 Hold After RDu

0

 

ns

tRR

RD Pulse Width

160

 

ns

tAD

CS, A0 to Data Out Delay

 

130

ns

tRD

RDv to Data Out Delay

0

130

ns

tDF

RDu to Data Float Delay

 

85

ns

DBB WRITE

 

 

 

 

 

 

 

 

 

 

 

Symbol

Parameter

 

Min

Max

Units

 

 

 

 

 

 

tAW

CS, A0 Setup to WRv

 

0

 

ns

tWA

CS, A0 Hold After WRu

 

0

 

ns

tWW

WR Pulse Width

 

160

 

ns

tDW

Data Setup to WRu

 

130

 

ns

tWD

Data Hold After WRu

 

0

 

ns

17

Page 17
Image 17
Intel UPI-C42, UPI-L42 specifications AC Characteristics, DBB Read, DBB Write