State Machine Transitions

Transition

From State

To State

 

Event/Action

Number

 

 

 

 

 

0

Start

Not Ready To Switch

Event:

Reset.

On

Action:

The drive self-tests and/or self-initializes.

 

 

 

 

 

Event:

The drive has self-tested and/or initialized

1

Not Ready To

 

successfully.

Switch On Disabled

 

Switch On

Action:

Activate communication and process data

 

 

 

 

 

monitoring

 

 

 

 

 

 

 

 

 

2

Switch On Disabled

Ready to Switch On

Event:

‘Shutdown’ command received from host.

 

 

Action:

None.

 

 

 

3

 

 

Event:

‘Switch On’ command received from host.

Ready to Switch On

Switched On

 

 

Action:

The power section is switched on if it is not

 

 

 

already switched on.

 

 

 

 

4

Switched On

Operation Enable

Event:

‘Enable Operation’ command received from host.

 

 

Action:

The drive function is enabled.

 

 

 

5

 

 

Event:

‘Disable Operation’ command received from

Operation Enable

Switched On

host.

 

 

 

 

Action:

The drive operation will be disabled.

6

Switched On

Ready to Switch On

Event:

‘Shutdown’ command received from host.

Action:

The power section is switched off.

 

 

 

7

Ready to Switch On

Switch On Disabled

Event:

‘Quick stop’ command received from host.

Action:

None

 

 

 

8

 

 

Event:

‘Shutdown’ command received from host.

Operation Enable

Ready to Switch On

Action:

The power section is switched off immediately,

 

 

 

and the motor is free to rotate if unbraked

 

 

 

 

9

 

 

Event:

‘Disable Voltage’ command received from host.

Operation Enable

Switch On Disabled

Action:

The power section is switched off immediately,

 

 

 

and the motor is free to rotate if unbraked

 

 

 

 

 

 

 

Event:

‘Disable Voltage’ or ‘Quick Stop’ command

 

 

 

received from host.

10

 

 

 

Switched On

Switch On Disabled

Action:

The power section is switched off immediately,

 

 

 

 

 

 

and the motor is free to rotate if unbraked

 

 

 

 

 

 

 

 

 

11

Operation Enable

Quick Stop Active

Event:

‘Quick Stop’ command received from host.

Action:

The Quick Stop function is executed.

 

 

 

 

 

 

 

‘Quick Stop’ is completed or ‘Disable Voltage’

12

 

 

Event:

command received from host. This transition

Quick Stop Active

Switch On Disabled

is possible, if the Quick-Stop-Option-Code is

 

 

 

 

 

different 5 (Stay in Quick-Stop)

 

 

 

Action:

The power section is switched off.

13

All States

Fault Reaction

Event:

A fault has occured in the drive.

Active

Action:

Execute appropriate fault reaction.

 

 

14

Fault Reaction

 

Event:

Fault reaction is completed.

Fault

 

 

 

The drive function is disabled, the power section

Active

Action:

 

 

may be switched off.

 

 

 

 

 

 

 

Event:

‘Fault Reset’ command is recieved from the host.

 

 

 

 

 

 

 

 

 

A reset of the fault condition is carried out if no

15

Fault

Switch On Disabled

 

fault exists currently on the drive. After leaving

Action:

the ‘Fault’ state the Bit ‘Fault Reset’ of the

 

 

 

 

 

 

 

controlword has to be cleared by

 

 

 

 

the host.

 

 

 

 

‘Enable Operation’ command received from

16

Quick Stop Active

Operation Enable

Event:

host. This transition is possible if the Quick-Stop-

 

Option-Code is 5,6,7 or 8.

 

 

 

Action:

The drive function is enabled

Table 4.2: State Machine Transitions

26

MDrivePlus CANopen R020507

Page 34
Image 34