14

12

13

11

14

11

13

12

13

11

14

12

 

Index Pulse

 

Home Switch

 

Negative Limit Switch

Figure 7.8: Homing on the Home Switch and Index Pulse - Negative Initial Move

Methods 15 and 16: Reserved

These methods are reserved for future expansion of the homing mode.

Methods 17 to 30: Homing without an Index Pulse

These methods are similar to methods 1 to 14 except that the home position is not dependent on the index pulse but only Dependent on the relevant home or limit switch transitions. For example methods 19 and 20 are similar to methods 3 and 4 as shown in the following diagram.

19

19

20

20

Home Switch

Figure 7.9: Homing without an Index Pulse

Methods 31 and 32: Reserved

These methods are reserved for future expansion of the homing mode.

46

MDrivePlus CANopen R020507

Page 54
Image 54
Intelligent Motion Systems DSP-402 manual Methods 15 and 16 Reserved, Methods 17 to 30 Homing without an Index Pulse