Note: A fault condition is caused by a problem with the battery. The charger may indicate a fault because the battery is too hot or cold to charge reliably. Charge batteries between 0°C to 45°C (32°F to 113°F). If the amber indicator starts flashing on the second attempt, the battery should be discarded.

4-Pack Charger Cycle Times for PL4 Batteries

Percentage Charged

Time

Battery 80% Charged

2.5 hrs.

 

 

Battery Fully Charged

5 hrs.

 

 

These times are for completely discharged batteries. Batteries that are only partially discharged will take less time to reach their charged state. You can use batteries that have reached 80% of their charge capacity, but we recommend you allow the batteries to reach a full charge to maintain maximum battery life.

The 4-pack battery charger has a safety feature that stops charging a battery after 6 hours regardless of its charge state.

Do not allow your battery charger to come in contact with any conductive material. It creates a short circuit that could cause burns and other injuries or could start a fire. Use of any charger not approved specifically by Intermec for use with its batteries could cause damage to the battery pack or the printer and will void the warranty.

Attention: Le chargeur de batterie ne doit pas entrer en contact avec un matériel conducteur. Dans le cas contraire, un court-circuit risque d’entraîner des brûlures et d’autres blessures ou de provoquer un incendie. L’emploi d’un chargeur non approuvé de façon spécifique par Intermec pour utilisation avec ses batteries risque d’endommager le bloc-batterie ou l’imprimante et annulera la garantie.

12

EasyCoder PL4 Printer User’s Guide

Page 12
Image 12
Intermec manual Pack Charger Cycle Times for PL4 Batteries, Percentage Charged Time