9 TROUBLESHOOTING
NUMBER OF | ERROR CODE | POSSIBLE SOLUTION |
FLASHES | DESCRIPTION |
|
|
|
|
7 | Remote Fault | Check to make sure joystick is connected properly. Turn Joystick off then on. |
|
| Contact Invacare/Dealer for service. |
|
|
|
8 | Controller Fault | Contact Invacare/Dealer for service. |
|
|
|
9 | Communications Fault | Check joystick cable connections. Check joystick cable and connectors for damage. |
|
| Contact Invacare/Dealer for service. |
|
|
|
10 | General Fault | Contact Invacare/Dealer for service. |
11Incompatible or Wrong type of remote connected. Contact Invacare/Dealer for service. incorrect Remote
MPJ™+, PSR+, PSF+ Joysticks or Displays
SYMPTOM | PROBABLE CAUSE | SOLUTIONS |
|
|
|
LEFT BRAKE FAULT or RIGHT BRAKE | Motor lock levers disengaged (Error | Engage motor lock levers. Refer to Disengaging/Engaging |
FAULT displays and wheelchair does not | code E9 or E10). | Motor Lock Levers on page 57. |
drive. |
|
|
|
|
|
CHARGER PLUGGED IN displays. | Battery charger connected (Error | Unplug battery charger from the wheelchair. Refer to |
| code E28). | Charging Batteries on page 53. |
|
|
|
BATTERY FAULT displays and the wheelchair | Batteries need to be charged (Error | Charge batteries. Refer to Charging Batteries on page 53. If |
does not drive. | code E14). | batteries fail to charge properly, check battery charger or |
|
| replace batteries. Refer to Replacing the Batteries and/or |
|
| Battery Cables on page 83. |
|
|
|
JOYSTICK TIMEOUT displays and the | Joystick or input device is | Turn off power, reconnect the joystick of input device and |
wheelchair does not drive. | disconnected (Error code 32). | turn power on. |
|
|
|
Invacare® FDX® | 94 | Part No 1163181 |