SECTION 9—BATTERIES

Using the Proper Batteries

NOTE: For this procedure, refer to FIGURE 9.1.

1.Place battery on ground/flat surface.

2.Visually draw a horizontal and vertical centerline through the middle of battery (FIGURE 9.1).

3.Position the battery so that the terminals are above the horizontal centerline.

4.Visually inspect the battery to ensure the correct position of the POSITIVE and NEGATIVE terminals (FIGURE 9.1).

WARNING

Batteries with terminal configuration as shown below MUST be used. Batteries that have the reverse terminal configuration MUST NOT be used - otherwise injury and damage may occur.

Use This Configuration

DO NOT Use

NEGATIVE (-)

 

 

 

POSITIVE (+)

Battery Terminal

 

Battery Terminal

 

 

 

NEGATIVE (-)

Battery Terminal

U1 Battery

POSITIVE (+)

U1 Battery

 

Battery Terminal

 

 

FIGURE 9.1 Using the Proper Batteries