Electrical Requirements for Booster Tanks

Technical Manual (07610‐003‐78‐18)

Electrical Requirements for Booster Tanks

40° F Rise ‐ 12 KW Booster

 

 

 

 

Rinse

 

 

 

Volts

Phase

 

Freq

Heater

 

FLA

 

 

 

 

 

Amps

 

 

 

208

1

60

57.7 A

 

57.7 A

 

 

 

 

 

 

 

 

 

230

1

60

47.9 A

 

47.9 A

 

 

 

 

 

 

 

 

 

208

3

60

33.3 A

 

33.3 A

 

 

 

 

 

 

 

 

 

230

3

60

27.7 A

 

27.7 A

 

 

 

 

 

 

 

 

 

460

3

60

13.8 A

 

13.8 A

 

 

 

 

 

 

 

 

 

70° F Rise ‐ 18 KW Booster

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rinse

 

 

 

Volts

Phase

 

Freq

Heater

 

FLA

 

 

 

 

 

Amps

 

 

 

208

1

 

60

82.7 A

 

82.7 A

 

 

 

 

 

 

 

 

 

230

1

 

60

71.9 A

 

71.9 A

 

 

 

 

 

 

 

 

 

208

3

 

60

47.7 A

 

47.7 A

 

 

 

 

 

 

 

 

 

230

3

 

60

41.5 A

 

41.5 A

 

 

 

 

 

 

 

 

 

460

3

 

60

20.7 A

 

20.7 A

 

 

 

 

 

 

 

 

 

Note: 0n the 208 volt machines, the rinse heater is actually rated at 17.2 KW