The other steam outlet (on the
IMPORTANT! Be careful not to exchange the two pipes.
ELECTRIC CONNECTION OF SHOWER ENCLOSURE
(MOD. ELT10/11)
Remove the insulating protective devices from the electric cable on the corner of the tub (coming from the electric box of the tub), and connect the cable to the junction box (✐ 10, details 1 and 2), respecting its polarity (brown: phase; blue: neutral; green and yellow: earth).
•Connect the two cables coming from the electric wiring box, positioned in the left corner, for the tub (✐ 10, detail 1).
•Take off the wiring junction box cover, remove the insulat- ing protection from the wires of cable B and connect this to the terminal board (detail 2), according to polarity (brown: phase, blue: neutral, yellow/green: earth).
•Repeat the same operations for the cable (A) with only two wires, connecting it to the right terminal board.
Carefully tighten the cable clamp, and close the junction box, taking care to position its lid correctly.
UNIPOTENTIAL CONNECTION
(MOD.ST2)
In ST2 models, pass the ), through the cable clamp on the tub rim (✐ 10, detail 3) and connect it to the terminal near the pump, marked with symbol
.
Carefully tighten the cable clamp, in order to avoid dripping under the tub.
Installation of wall with mirror
Apply a small quantity of silicone around the holes indicated in
✐11, detail 1.
Position the wall with mirror, place it against the
Overturn the structure and position the upper guide on the fixed glass pane. Repeat these operations for the lower guide (stages 5, 6, 7, 8).
Apply silicone to the heads of the guides that are still free (stage 9), and fasten the upright to the guides by means of 4 (2+2) screws (stage 10).
Installation of fixed glass panel
Apply silicone around the holes on the tub rim (✐ 13, details 1, 4, 5 and 5a).
Position the assembled glass pane on the tub rim and fasten it to the uprights of the
From under the tub rim, fasten the glass pane by means of: 4 screws for the lower guide (✐ 13, detail 4).
2 (1+1) screws for the uprights (✐ 13, details 5 and 5a).
Fasten the
Apply a small quantity of silicone to the entire mating profile of the
Carefully apply silicone to the mating profile of the walls with the tub edge (✐ 14, details 2 and 4) and of the walls with the uprights of the glass panes (detail 3).
These applications of silicone ensure that the system is water- proof during normal use, and even in particular conditions, for instance when the shower is directed to the points of junction between the various elements.
Installation of roof (if any)
This operation must be performed by at least two persons. Place the roof upon the
Pass the rubber pipe (the only pipe that is not connected and comes from the solenoid valve assembly) through the hole on he roof (detail 2). Fasten it to the pipe fitting of the revolving shower (detail 3).
Assembly of fixed glass panel
Remove from the wooden crate the fixed glass pane, the sliding door, the upright, the upper guide, the lower guide, and the two compensators for fastening the structure to the wall.
The lower guide is the one with the gasket.
(See ✐ 12): Apply silicone to the lower guide for all the length of the glass pane (stage 1) and on its head (stage 2).
Position the guide on the
Connection of telephone (if any)
Version ELT10 is equipped with a speakerphone whose con- trols are built into the electronic display.
To activate it, connect it to a suitably provided telephone socket, using the cable that is bundled and fastened to the back of the shower enclosure (it is approximately 10 metres long). For this connection, you must provide a track in the wall or an external raceway in which the cable will be routed up to the telephonic socket.
It is the customer’s responsibility to choose the position of the telephone socket, depending on the length of the cable sup- plied.
12