Page 25

TM-1020 Series Progressive Scan Shutter Cameras

3.6.5External VINIT with Pulse Width (TM-1020-15 Only)

FIGURE 14. External VINIT with Pulse Width (TM-1020-15 Only)

Hd

VINIT

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32H

FDV

9H Discharge Pulse

9H

Transfer

Gate

X

FDV is output at the internal VINIT timing

S9 Exposure Time = X (H)

The TM-1020 series can be reset with external reset pulse (VINIT). Set the dial switch to “9.” Apply a pulse-width control VINIT signal generated from an external event trigger to the camera. The internal reset pulse will be latched to HD and at the 9th HD timing from the external pulse leading edge (negative going edge). The CCD discharge pulse will be generated to clear the images. The internal VINIT will be generated at the following edge (positive going edge) of the external pulse, resetting the internal timing including the video sync. The shutter speed is the same as the external pulse width, but the integration delays 9H from the leading edge. For the immediate reset option, please contact JAI, Inc.

For the progressive format, one frame of video output will start from the rising edge of the pulse width control. When VINIT is kept high (5V), subsequent frames will contain black or invalid video until the next falling edge of Vinit triggers another frame.

Operation

Page 35
Image 35
JAI operation manual External Vinit with Pulse Width TM-1020-15 Only