Page 10

TM-1020 Series Progressive Scan Shutter Cameras

2.2.3Shutter Speed Control Dial (LVDS/RS-422 version)

Shutter speed can be selected by switching the shutter dial to the appropriate setting (0 through 9). The factory default settings correspond to the shutter speeds as shown in Table 5 below.

TABLE 5.

Shutter Speed Control Dial

 

 

 

 

 

 

Manual

Async

 

 

 

 

0

 

no shutter

no shutter

 

 

 

 

1

 

1/60

1/16,000

 

 

 

 

2

 

1/125

1/8,000

 

 

 

 

3

 

1/250

1/4,000

 

 

 

 

4

 

1/500

1/2,000

 

 

 

 

5

 

1/1000

1/1,000

 

 

 

 

6

 

1/2,000

1/500

 

 

 

 

7

 

1/4,000

1/250

 

 

 

 

8

 

1/8,000

1/125

 

 

 

 

9

 

1/16,000

Ext. pulse-width control

 

 

 

 

2.2.4RS-232 Communication Cable (LVDS/RS-422 version)

FIGURE 4. Serial Communication Cable RS-232B-12

2000±20mm

40±3mm 1925±10mm

MALE

75mm±5mm

190±5mm

1 6

5 9

FEMALE

The RS-232 controller set CS-232E includes the RS-232B-12 interface cable, software disk, and a quick-start card. The TM-1020 (RS-422 and LVDS/RS-422 version) camera’s built-in look-up table (LUT) can be controlled by an external RS-232 interface. The camera settings can be programmed or changed using the communication cable and software. Commands from the RS-232 interface will over- write the rear panel switch settings of the camera. Please refer to the AccuPiXEL Series Camera- Control Software manual for details on the graphical user interface.