2.2.3 Shutter Speed Control Dial (LVDS/RS-422 version)
Shutter speed can be selected by switching the shutter dial to the appropriate setting (0 through 9). The
factory default settings correspond to the shutter speeds as shown in Table 5 below.
TABLE 5. Shutter Speed Control Dial
2.2.4 RS-232 Communication Cable (LVDS/RS-422 version)
FIGURE 4. Serial Communication Cable RS-232B-12
The RS-232 controller set CS-232E includes the RS-232B-12 interface cable, software disk, and a
quick-start card. The TM-1020 (RS-422 and LVDS/RS-422 version) camera’s built-in look-up table
(LUT) can be controlled by an external RS-232 interface. The camera settings can be programmed or
changed using the communication cable and software. Commands from the RS-232 interface will over-
write the rear panel switch settings of the camera. Please refer to the AccuPiXEL Series Camera-
Control Software manual for details on the graphical user interface.
Manual Async
0 no shutter no shutter
1 1/60 1/16,000
2 1/125 1/8,000
3 1/250 1/4,000
4 1/500 1/2,000
5 1/1000 1/1,000
6 1/2,000 1/500
7 1/4,000 1/250
8 1/8,000 1/125
9 1/16,000 Ext. pulse-width control
MALE
40±3mm
75mm±5mm
FEMALE
1925±10mm
2000±20mm
190±5mm
6
1
59