Page 34

TM-1020 Series Progressive Scan Shutter Cameras
LVDS-Version Camera RS-232 Commands
4 LVDS-Version Camera RS-232 Commands
The LVDS-version camera can be controlled via RS-232 commands. The Start character is always “:”
and the end character is always “CR” (return). For example, to set Asynchronous Pulse Width Mode,
send the command :SA9”CR” to the camera. The following table contains RS-232 commands that can
be used to control the camera.
TABLE 7. RS-232 Command List
First
Character
Second
Character
Third
Character Response Functions
1“S” (shutter) “M” (Manual) “0” - “9”
Mode
ACK Manual Shutter Mode
“A” (ASYNC) “0” - “8”
Mode
ACK Async Shutter Mode
“9” (Pulse
Width Mode)
ACK Async Pulse Width Mode
2“G” (Gain) “M” “00” - “FF” ACK Gain Control
3“V” (A/D Vref) “T” (Top) “00” - “FF” ACK Vtop reference setting
“B” (Bottom) “00” - “FF” ACK Vbtm reference setting
4“W” (Write) “P” (Page) “0” - “6” ACK Write current setting to Page
EEPROM
“U” (User) “A” - “D” ACK Write current setting to User
EEPROM
“S” (System) “A” - “D” ACK Write current setting to System
EEPROM
5“L” “P” (Page) “0” - “6” ACK Restore setting from Page
EEPROM
“U” (User) “A” - “D” ACK Restore setting from User
EEPROM
“S” (System) “A” - “D” ACK Restore setting from System
EEPROM
“N” (kNee) “0” - “9” ACK Load Preset Knee Table
6“R” (Report) “P” (Page) “0” - “6” ACK ACK + “P” + (“9” - “F”) + 16
bytes
“U” (User) “A” - “D” ACK ACK + “U” + (“A” - “D”) + 6
bytes
“S” (System) “A” - “D” ACK ACK + “S” + (“A” - “D”) + (6
bytes)
“R” (Current) ACK ACK + “RR” + 16 bytes
“X” (Execute) ACK Set Camera with loaded data
“D” (Date) info Report CPU program version