Page 34

TM-1020 Series Progressive Scan Shutter Cameras

4 LVDS-Version Camera RS-232 Commands

The LVDS-version camera can be controlled via RS-232 commands. The Start character is always “:” and the end character is always “CR” (return). For example, to set Asynchronous Pulse Width Mode, send the command :SA9”CR” to the camera. The following table contains RS-232 commands that can be used to control the camera.

TABLE 7. RS-232 Command List

 

First

Second

Third

Response

Functions

 

Character

Character

Character

 

 

 

 

 

 

1

“S” (shutter)

“M” (Manual)

“0” - “9”

ACK

Manual Shutter Mode

 

 

 

Mode

 

 

 

 

 

 

 

 

 

 

“A” (ASYNC)

“0” - “8”

ACK

Async Shutter Mode

 

 

 

Mode

 

 

 

 

 

 

 

 

 

 

 

“9” (Pulse

ACK

Async Pulse Width Mode

 

 

 

Width Mode)

 

 

 

 

 

 

 

 

2

“G” (Gain)

“M”

“00” - “FF”

ACK

Gain Control

 

 

 

 

 

 

3

“V” (A/D Vref)

“T” (Top)

“00” - “FF”

ACK

Vtop reference setting

 

 

 

 

 

 

 

 

“B” (Bottom)

“00” - “FF”

ACK

Vbtm reference setting

 

 

 

 

 

 

4

“W” (Write)

“P” (Page)

“0” - “6”

ACK

Write current setting to Page

 

 

 

 

 

EEPROM

 

 

 

 

 

 

 

 

“U” (User)

“A” - “D”

ACK

Write current setting to User

 

 

 

 

 

EEPROM

 

 

 

 

 

 

 

 

“S” (System)

“A” - “D”

ACK

Write current setting to System

 

 

 

 

 

EEPROM

 

 

 

 

 

 

5

“L”

“P” (Page)

“0” - “6”

ACK

Restore setting from Page

 

 

 

 

 

EEPROM

 

 

 

 

 

 

 

 

“U” (User)

“A” - “D”

ACK

Restore setting from User

 

 

 

 

 

EEPROM

 

 

 

 

 

 

 

 

“S” (System)

“A” - “D”

ACK

Restore setting from System

 

 

 

 

 

EEPROM

 

 

 

 

 

 

 

 

“N” (kNee)

“0” - “9”

ACK

Load Preset Knee Table

 

 

 

 

 

 

6

“R” (Report)

“P” (Page)

“0” - “6”

ACK

ACK + “P” + (“9” - “F”) + 16

 

 

 

 

 

bytes

 

 

 

 

 

 

 

 

“U” (User)

“A” - “D”

ACK

ACK + “U” + (“A” - “D”) + 6

 

 

 

 

 

bytes

 

 

 

 

 

 

 

 

“S” (System)

“A” - “D”

ACK

ACK + “S” + (“A” - “D”) + (6

 

 

 

 

 

bytes)

 

 

 

 

 

 

 

 

“R” (Current)

 

ACK

ACK + “RR” + 16 bytes

 

 

 

 

 

 

 

 

“X” (Execute)

 

ACK

Set Camera with loaded data

 

 

 

 

 

 

 

 

“D” (Date)

 

info

Report CPU program version

 

 

 

 

 

 

LVDS-Version Camera RS-232 Commands

Page 44
Image 44
JAI TM-1020 operation manual LVDS-Version Camera RS-232 Commands