STEP 4: ELECTRICAL CONNECTIONS
Power Requirements
120 VAC, 60 Hz., single phase.
PRG3010 - | 4 | Amp. Max. |
PRG3610 - | 7 | Amp. Max. |
PRG4810 - | 13 | Amp. Max. |
(Use 15 Amp. Circuit)
Always disconnect electric supply cord from the wall outlet or service disconnect before servicing this appliance.
Observe all governing codes and ordinances when grounding, in the absence of which, observe National Electrical Code ANSI/NFPA No.
Recommended Grounding Method
This appliance is factory equipped with a power supply cord with a
THIS THIRD GROUND PRONG SHOULD NOT, UNDER
ANY CIRCUMSTANCES, BE CUT OR REMOVED.
(SEE FIGURE 9)
Receptacle Box
Cover Plate
Three
Prong
Plug
Ground
Prong
Three Prong
Receptacle
FIGURE 9
STEP 5: GAS REQUIREMENTS
Verify the type of gas supplied to the location.
The range is shipped from the factory set up and adjusted for natural gas or LP gas (propane), depending on model ordered.
Natural Gas Requirements
Connection: 1/2 N.P.T. Minimum 5/8 dia. flex line.
Pressure: 6 to 14 W.C.
LP Gas Requirements
Connection: 1/2 N.P.T., Minimum 5/8 dia. flex line.
Pressure: 11 to 14 W.C.
A regulator is required at the LP source to provide a maximum of 14 W.C. to the range regulator.
Hook Up
A manual valve must be installed external to the appliance, in a location accessible from the front for the purpose of shutting off the gas supply. The supply line must not protrude beyond the back of the unit. Make sure the gas supply is turned off at the wall valve before connecting the appliance.
The gas supply connections should be made by a competent technician and in accordance with local codes or ordinances. In the absence of a local code, the installation must conform to the National Fuel Gas Code ANSI
CAUTION
The appliance must be isolated from the building’s gas supply piping system by closing its individual manual
The appliance and its individual
When checking the manifold gas pressure, the inlet pressure to the regulator should be at least 7.0 W. C. for natural gas.
**The flex line for the gas supply must be metal and be approved by an approved certifying agency (AGA, CGA, or U.L.). Never use a hose made of rubber or other synthetic material, as the heat may cause the hose to melt and develop leaks.