John Lewis JLBIOS609 manual Electrical connection, 1This oven must be earthed, For UK use only

Models: JLBIOS609

1 60
Download 60 pages 17.35 Kb
Page 53
Image 53

Electrical connection

The oven is designed to be connected to 230- 240V~(50Hz) electricity

supply.

The oven has an easily accessible terminal block which is marked as

follows:

Letter L

-

Live terminal

Letter N

-

Neutral terminal

E- Earth terminal

1This oven must be earthed!

The cable used to connect the oven to the electrical supply must comply to the specifica- tions given below.

For UK use only

Connection

Min. size

Cable/flex

Fuse

via

Cable/

type

flex

 

 

 

 

 

 

 

 

Cooker

2,5 mm2

PVC/PVC

min:

Control

 

twin and

15A

Circuit

 

earth

max:

 

 

 

20A

 

 

 

 

It is necessary that you install a double pole switch between the oven and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current regulations.

The switch must not break the yellow and green earth cable at any point.

Important

After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 50°C above the ambient temperature.

Before the oven is connected, check that the main fuse and the domestic installation can support the load; and that the power supply is properly earthed.

The manufacturer declines any responsi- bility should these safety measures not be carried out.

53

Page 53
Image 53
John Lewis JLBIOS609 manual Electrical connection, 1This oven must be earthed, For UK use only