Connecting Power

IDP 75, 250, 800, and 8200 Installation Guide

Figure 11: 1 RU Device (IDP 75) Midmount Bracket

2.Place the chassis into position between rack posts in the equipment rack and align the rack mounting bracket holes with the rack post holes.

CAUTION: Be sure to leave at least two inches of clearance on the sides of each chassis for the cooling air inlet and exhaust ports.

3.Attach the rack-mounting brackets on each chassis to the rack with the appropriate rack screws.

4.(For 2 RU devices only) Attach the other two midmount brackets to the chassis and the back of the rack to hold the device securely in place.

Connecting Power

NOTE: Power is provided to the IDP sensor using 90/264 VAC from your facility.

To connect power to your sensor:

1.Connect the provided power cable to the receptacle on the power supply at the rear of each chassis.

2.Connect the other end of the power cable to the electrical outlet.

3.(For IDP 800 and 8200 sensors only) Connect the second power cable to the receptacle on the second power supply. This step is optional for the IDP 8200 sensor.

4.(For IDP 800 and 8200 sensors only) Connect the other end of the second power cable to the electrical outlet. This step is optional for the IDP 8200 sensor.

NOTE: If you have two power supplies and do not connect both of them, the PS FAIL warning light illuminates and the sensor emits a warning tone when it is turned on.