Juniper Networks IDP250, IDP8200, IDP75 manual IDP 800 Technical Specifications

Models: IDP250

1 68
Download 68 pages 1.06 Kb
Page 64
Image 64
IDP 800 Technical Specifications

IDP 75, 250, 800, and 8200 Installation Guide

IDP 800 Technical Specifications

Tables 25–28 list the physical, AC power, power cord, and environmental technical specifications for the IDP 800 sensor.

Table 25: Physical Specifications

Specification

Value

 

 

Height

2 RU (2.9 inches)

 

 

Width

17 inches

 

 

Depth

20.5 inches

 

 

Weight

33.5 lbs

 

 

Table 26: AC Power Specifications

Specification

Nominal Value

Acceptable Range

 

 

 

AC input voltage

110/220 VAC, single phase

90 to 255 VAC

 

 

 

AC input line frequency

50/60 Hz

47 to 63 Hz

 

 

 

AC input current

4 A @ 110 VAC

 

 

2 A @ 220 VAC

 

 

 

 

Table 27: Power Cord Specifications

Country

Specifications

 

 

United States and Canada

„ UL-approved and CSA-certified

 

„ Flexible cord minimum spec: No. 18 (1.5 mm2), Type SVT

 

or SJT, 3-conductor

 

„ Current capacity of 10 A minimum

 

„ Earth-grounding attachment plug with NEMA 5-15P (10 A,

 

125 V) configuration

 

Table 28: Environmental Specifications

 

 

Specification

Value

 

 

Operating environment

0 to 35oC (ambient)

Non-operating environment

-10oto 70o C

50„ IDP 800 Technical Specifications

Page 64
Image 64