Juniper Networks IDP8200 Servicing the Device, Replacing a Power Supply IDP 800, and 8200 Only

Models: IDP250

1 68
Download 68 pages 1.06 Kb
Page 53
Image 53
Servicing the Device

Chapter 7

Servicing the Device

This chapter describes the service and maintenance of various components in your IDP sensors. It has the following sections:

„Replacing a Power Supply (IDP 800, and 8200 Only) on page 39

„Replacing a Hard Drive (IDP 800 and 8200 Only) on page 40

Replacing a Power Supply (IDP 800, and 8200 Only)

The power supplies on the IDP 75 and 250 sensors are in a fixed configuration so you cannot replace them. The IDP 800 sensor has two hot swappable power supplies while the IDP 8200 sensor has three.

If a device has two replaceable power supplies, you can hot swap one while the device is running. Contact Juniper Networks if you want to purchase a spare power supply.

Remove a Power Supply

To remove a power supply:

1.Go to the back of the device and locate the power supply you want to remove.

2.Locate the horizontal handle and the red lever in the upper left corner of the power supply.

3.Lift the handle and push the lever to the right to unlatch the power supply.

4.With the lever pushed to the right, pull on the handle firmly to dislodge the power supply from its seating.

5.Let go of the lever and slide out the power supply from the handle.

6.Let go of the handle and use both hands to slide the power supply the rest of the way out.

Replacing a Power Supply (IDP 800, and 8200 Only) „ 39

Page 53
Image 53
Juniper Networks IDP8200 Servicing the Device, Replacing a Power Supply IDP 800, and 8200 Only, Remove a Power Supply