The DC power supply in an EX8200 switch is a hot-removable and hot-insertable field-replaceable unit (FRU). You remove DC power supplies from the front of the chassis.

NOTE: EX8208 switches support 2000 W DC power supplies.

EX8216 switches support 3000 W DC power supplies.

CAUTION: Before you remove a power supply, ensure that you have power supplies sufficient to power the switch left in the chassis. See “Calculating Power Requirements for an EX8208 Switch” on page 114 and Calculating Power Requirements for an EX8216 Switch.

Before you remove a DC power supply from the switch:

Ensure that you understand how to prevent ESD damage. See “Prevention of Electrostatic Discharge Damage on EX Series Switches” on page 292.

Ensure that you have the following parts and tools available to remove a DC power supply from an EX8200 switch chassis:

Electrostatic discharge (ESD) grounding strap

Phillips (+) screwdriver, number 1