Juniper Networks EX8208 manual Copyright 2010, Juniper Networks, Inc 177

Models: EX8208

1 338
Download 338 pages 53.12 Kb
Page 203
Image 203

Chapter 10: Connecting the Switch

The provided cable lugs in an EX8216 switch are sized for 2 AWG (33.6 mm2) power source cables. The DC power source cables that you provide must be 2 AWG (33.6 mm2),minimum60°Cwire. Werecommendthatyouinstallheat-shrinktubinginsulation around the power cables and lugs.

3/8 in. (9.5 mm) nut driver or socket wrench

Phillips (+) screwdriver, number 2

Multimeter

WARNING: Ensure that the power cords do not block access to switch components or drape where people can trip on them.

To connect DC power to an EX8200 switch:

1.Attach the electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to the ESD point on the chassis.

2.Flip the Enable switch on the power supply faceplate to the Standby position.

NOTE: It might be necessary to slide each power supply partially out of the chassis, in order to easily connect the DC power source cables to the DC power input terminals. See “Removing a DC Power Supply from an EX8200 Switch” on page 209.

3.Remove the plastic cable cover from the DC power input terminals, using the number 2 Phillips (+) screwdriver to loosen the screw (see Figure 68 on page 177).

Figure 68: Removing the Plastic Cable Cover on a DC Power Supply in an EX8200 Switch

4.Remove the washers and nuts from each DC power input terminal, using the 3/8-in. (9.5 mm) nut driver or socket wrench to loosen the nuts. Leave the bolts installed on the input terminals.

Copyright © 2010, Juniper Networks, Inc.

177

Page 203
Image 203
Juniper Networks EX8208 manual Copyright 2010, Juniper Networks, Inc 177