Calculating Power Requirements for an EX8208 Switch on page 114

AC Power Cord Specifications for an EX8200 Switch

Each AC power supply has a single AC appliance inlet located on the power supply that requires a dedicated AC power feed. Most sites distribute power through a main conduit that leads to frame-mounted power distribution panels, one of which can be located at the top of the rack that houses the switch. An AC power cord connects each power supply to the power distribution panel.

Each detachable AC power cord is 2.5 meters (approximately 8 feet) long. The appliance coupler at the female end of the cord inserts into the AC appliance inlet on the faceplate of the AC power supply. The coupler type is C19 as described by the International Electrotechnical Commission (IEC) standard 60320. The plug at the male end of the power cord fits into the power source outlet that is standard for your geographical location.

NOTE: In North America, AC power cords must not exceed 4.5 meters (approximately 15 feet) in length, to comply with National Electrical Code (NEC) Sections 400-8 (NFPA 75, 5-2.2) and 210-52 and Canadian Electrical Code (CEC) Section 4-010(3). The cords shipped with the switch are in compliance.

Table 47 on page 112 lists the AC power cord specifications for an EX8200 switch for the countries and regions listed in the table.

Table 47: AC Power Cord Specifications for an EX8200 Switch

Country/Region

Electrical Specifications

Plug Standards

Australia

250 VAC, 15 A, 50 Hz

AS/NZS 3112

China

250 VAC, 16 A, 50 Hz

GB 1002

Europe (except Italy,

250 VAC, 16 A, 50 Hz

CEE (7) VII

Switzerland, and United

 

 

Kingdom)

 

 

Italy

250 VAC, 16 A, 50 Hz

CEI 23-16

Japan

250 VAC, 16 A, 50 Hz

NEMA 6–20

 

 

NEMA L6–20