Juniper Networks EX8208 manual Copyright 2010, Juniper Networks, Inc

Models: EX8208

1 338
Download 338 pages 53.12 Kb
Page 324
Image 324

Complete Hardware Guide for EX8208 Ethernet Switches

strømbryteren på brytertavlen som betjener likestrømkretsen, slå strømbryteren AV og teipe bryterhåndtaket på strømbryteren i AV-stilling.

Aviso Antes de executar um dos seguintes procedimentos, certifique-se que desligou a fonte de alimentação de energia do circuito de corrente contínua. Para se assegurar que toda a corrente foi DESLIGADA, localize o disjuntor no painel que serve o circuito de corrente contínua e coloque-o na posição OFF (Desligado), segurando nessa posição a manivela do interruptor do disjuntor com fita isoladora.

¡Atención! Antes de proceder con los siguientes pasos, comprobar que la alimentación del circuito de corriente continua (CC) esté cortada (OFF). Para asegurarse de que toda la alimentación esté cortada (OFF), localizar el interruptor automático en el panel que alimenta al circuito de corriente continua, cambiar el interruptor automático a la posición de Apagado (OFF), y sujetar con cinta la palanca del interruptor automático en posición de Apagado (OFF).

Varning! Innan du utför någon av följande procedurer måste du kontrollera att strömförsörjningen till likströmskretsen är bruten. Kontrollera att all strömförsörjning är BRUTEN genom att slå AV det överspänningsskydd som skyddar likströmskretsen och tejpa fast överspänningsskyddets omkopplare i FRÅN-läget.

Related Topics General Safety Guidelines and Warnings for EX Series Switches on page 263

General Electrical Safety Guidelines and Warnings for EX Series Switches on page 291

DC Power Electrical Safety Guidelines for EX Series Switches on page 296

DC Power Grounding Requirements and Warning for EX Series Switches on page 298

DC Power Wiring Sequence Warning for EX Series Switches on page 299

DC Power Wiring Terminations Warning for EX Series Switches on page 301

DC Power Grounding Requirements and Warning for EX Series Switches

An insulated grounding conductor that is identical in size to the grounded and ungrounded branch circuit supply conductors but is identifiable by green and yellow stripes is installed as part of the branch circuit that supplies the unit. The grounding conductor is a separately derived system at the supply transformer or motor generator set.

WARNING: When you install the switch, the ground connection must always be made first and disconnected last.

Waarschuwing Bij de installatie van het toestel moet de aardverbinding altijd het eerste worden gemaakt en het laatste worden losgemaakt.

Varoitus Laitetta asennettaessa on maahan yhdistäminen aina tehtävä ensiksi ja maadoituksen irti kytkeminen viimeiseksi.

298

Copyright © 2010, Juniper Networks, Inc.

Page 324
Image 324
Juniper Networks EX8208 manual Copyright 2010, Juniper Networks, Inc