All installations and services must be performed by qualified service personnel.
d.American National Standard
e.These
f.These
: The area around the furnace must be kept free and clear of combustible materials, especially papers and rags.
: This furnace is not to be used as a construction heater.
Listed below are definitions of “ COMBUSTIBLE MATERIAL” and “NON-
COMBUSTIBLE MATERIAL.”
COMBUSTIBLE MATERIAL:
Material made of or surfaced with wood, compressed paper, plant fibers, plastics or other material that will ignite.
NON-COMBUSTIBLE MATERIAL:
Material that will not ignite and burn. Such materials consist entirely of steel, iron, brick, tile, concrete, slate, glass or a plaster combination thereof.
MODELS CMA3/CMC1 | CLOSET | ALCOVE |
FRONT | 6” | 18” |
BACK | 0” | 0” |
SIDES | 0” | 0” |
VENT CONNECTOR(PVC) | 0” | 0” |
TOP | 0” | 0” |
PLENUM SIDES | 1” | 1” |
TOP AND SIDES OF DUCT | 1” | 1” |
BOTTOM OF DUCT | 1” | 1” |
Table 1
This heating appliance must be installed with clearances not less than the minimums shown above as well as ample clearance for easy access to the air filter, blower assembly, burner assembly, controls, and vent connections.
12