Thermo Products CMC1-50DV3N, CMC1-50D36N, CMC1-75D36N The LED will also flash once at power-up

Models: CMC1-75DV3N CMA3-75D36N CMA3-50D36N CMC1-75D36N CMC1-50D36N CMC1-50DV3N

1 65
Download 65 pages 47.5 Kb
Page 54
Image 54
The LED will also flash once at power-up.

All installations and services must be performed by qualified service personnel.

3 flashes, then pause

pressure switch stuck open

4 flashes, then pause

open high limit switch

6 flashes, then pause

115 volt AC power reversed

7 flashes, then pause

low flame sense signal

8 flashes, then pause

check ignitor or improper grounding

Continuous flashing

Flame has been sensed when

(no pause)

no flame should be present

(no call for heat)

The LED will also flash once at power-up.

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background: Power must be disconnected before servicing.

52

Page 54
Image 54
Thermo Products CMC1-50DV3N, CMC1-50D36N, CMC1-75D36N, CMA3-50D36N, CMA3-75D36N The LED will also flash once at power-up

FAQ

Who should perform installations and services for Thermo Products Furnaces?

All installations and services must be performed by qualified service personnel.

What should I do if the LED flashes once at power-up?

Power must be disconnected before servicing.

What do continuous flashing error codes indicate?

The LED will flash continuously when the flame has been sensed but no flame should be present.