Thermo Products CMA3-50D36N Ii. Furnace Specifications, Model, CMA3-75D36, Gas Supply Pressure

Models: CMC1-75DV3N CMA3-75D36N CMA3-50D36N CMC1-75D36N CMC1-50D36N CMC1-50DV3N

1 65
Download 65 pages 47.5 Kb
Page 9
Image 9

All installations and services must be performed by qualified service personnel.

II. FURNACE SPECIFICATIONS

MODEL

CMA3-50D36

 

CMA3-75D36

INPUT IN BTUH

 

50,000

 

75,000

 

OUTPUT IN BTUH

 

48,000

 

72,000

 

MAIN ORIFICE-NAT.

 

 

#42

 

 

MAIN ORIFICE-LP

 

 

#54

 

 

GAS SUPPLY PRESSURE

 

 

 

 

 

L.P. MINIMUM

 

11” IN.W.C.

 

NAT. MINIMUM

 

4.5”IN.W.C.

 

L.P. MAXIMUM

 

14” IN.W.C.

 

NAT. MAXIMUM

 

14” IN.W.C.

 

GAS MANIFOLD PRESSURE

 

 

 

 

 

L.P.

 

10.0” + .03 IN.W.C.

 

NAT.

 

3.5” + .03 IN. W.C.

 

INTAKE SIZE IN INCHES

 

 

2”

 

 

VENT SIZE IN INCHES

 

 

2”

 

 

NOMINAL TEMPERATURE RISE

 

55°F

 

65°F

 

SEASONAL EFFICIENCY (AFUE*)

 

 

95%

 

 

*ANNUAL FUEL UTILIZATION

 

 

 

 

 

EFFICIENCY

 

 

 

 

 

DIMENSIONS

 

 

 

 

 

CABINET SIZE

WIDTH 18” DEPTH 25-3/4" HEIGHT 57"

SUPPLY AIR OUTLET

 

WIDTH 12” DEPTH 12"

 

ELECTRICAL SUPPLY

 

115 VOLTS-- 60HZ --1/PH

 

FUSE OR HACR BREAKER

 

 

15 AMPS

 

 

TOTAL CURRENT AMPS

 

 

7.15 AMPS

 

 

NOMINAL ANTICIPATOR SETTING

 

0.8 MILLIAMPS

 

FILTER SIZE

 

(1) 18” X 24” X 1”

 

APPROXIMATE SHIPPING WEIGHT

175 LBS.

 

185 LBS.

BLOWER DATA

 

 

 

 

 

BLOWER MODEL

 

12-9T DIRECT DRIVE

 

MOTOR HORSEPOWER

 

 

1/2 PSC

 

 

MOTOR RPM

 

1065 (HIGH SPEED)

 

CFM @ .2 & .5 IN. W.C. SPEED

.2”

.5”

.2”

.5”

LOW

805

695

797

668

MD-LOW

1010

860

995

869

MD-HIGH

1196

1038

1210

1076

HIGH

1338

1162

1420

1259

FOR BURNER COMBUSTION INFORMATION REFER TO INITIAL STARTUP.

7

Page 9
Image 9
Thermo Products CMA3-50D36N Ii. Furnace Specifications, Model, CMA3-75D36, Gas Supply Pressure, Gas Manifold Pressure

FAQ

What are the main orifice sizes for natural and LP gas?

The main orifice sizes for natural gas are #42 and for LP gas are #54.

What is the seasonal efficiency AFUE for these models?

The seasonal efficiency AFUE for these models is 95%.

What is the electrical supply requirement for these models?

The electrical supply requirement is 115 volts, 60Hz, and 1 phase.