Thermo Products CMC1-50DV3N, CMC1-50D36N, CMC1-75D36N, CMA3-50D36N, CMA3-75D36N Terminations

Models: CMC1-75DV3N CMA3-75D36N CMA3-50D36N CMC1-75D36N CMC1-50D36N CMC1-50DV3N

1 65
Download 65 pages 47.5 Kb
Page 30
Image 30
Terminations

All installations and services must be performed by qualified service personnel.

Figure 10: Typical Construction Details of Sidewall Vent and Air Intake

Terminations

3.Finish the vent installation by caulking the annulus to seal around the two (2) holes where the thermoplastic pipes pass through the wall.

4.To prevent foreign material, insects, or small animals from entering the pipes, an optional vent or intake terminal (stainless steel) screen is available from Thermo Products under part no. 320219.

J.CONNECTING THE FURNACE TO ROOF VENT / AIR TERMINATIONS

The CMA/CMC is designed to be vented with either a concentric vent assembly or twin 2” pvc stacks. The concentric vent (AOPS7483) can be vented through the ceiling/roof either thru the existing roof jack or thru the 3” ceiling/roof flashing plate.

Concentric vent utilizing existing roof jack as a chase.

Follow instructions included with concentric vent kit AOPS7483.

Concentric vent without roof jack as a chase.

Follow instructions included with concentric vent kit AOPS7483.

Dual 2” vent/air termination kit AOPS7484

1.Remove roof jack assembly.

2.Place a 2” (2-holes) ceiling/roof flashing plate to the ceiling centering it over existing hole.

3.Place second flashing plate on roof over existing hole.

4.Plate must be sealed to roof to ensure a weather proof seal.

5.Secure plate to roof.

6.Drop pvc pipes thru holes in flashing plates.

7.Secure with hose clamps to flashing plate.

8.Seal with silicone type caulk.

28

Page 30
Image 30
Thermo Products CMC1-50DV3N, CMC1-50D36N, CMC1-75D36N, CMA3-50D36N, CMA3-75D36N, CMC1-75DV3N service manual Terminations

FAQ

Who should perform the installations and services?

All installations and services must be performed by qualified service personnel.

How to finish the vent installation?

Finish the vent installation by caulking the annulus to seal around the two 2 holes where the thermoplastic pipes pass through the wall.

What is required to prevent foreign material from entering the pipes?

An optional vent or intake terminal stainless steel screen is available from Thermo Products under part no. 320219.