All installations and services must be performed by qualified service personnel.

4. Vent Terminal Location Guidelines

4. Vent Terminal Location Guidelines: Bushes, shrubs, or any vegetation that may restrict the flow of flue products must be kept away from vent and air intake terminations. Terminations must also be kept clear of any leaves, weeds, combustible materials, snow, and ice build-up. Avoid locating the vent terminal over areas where dripping of condensate, or small pools of acidic condensate, could create a problem.

In addition to following any local code requirements, when possible, utilize the guidelines below in locating the vent terminal to help insure trouble-free operation of a sidewall vented furnace:

Avoid locating the vent terminal on a wall facing prevailing winds and wide- open areas. When impractical, choose a location that protects the vent from strong winds, such as behind a fence or hedge.

In geographical areas with considerable snowfall, it is advisable to locate the vent terminal much higher than the minimum 12-inches above ground to prevent blockage by snow accumulation or drifting.

The vent and combustion air terminations shall be checked periodically, at least at the start of each heating season, for restriction or blockage from foreign material in the exhaust vent or in the air intake piping. Clean the air intake and vent terminations when necessary.

I.Installation Of Outside Exhaust / Intake Terminations

1.After determining appropriate installation locations (suitable locations must observe all clearances specified in this manual), mark and cut two (2), 2-3/8 inch diameter holes in the outside wall for the outdoor terminal(s)

2.Measure and cut two (2), 2-inch diameter thermoplastic pipes 1-1/2 inches longer than the depth of the wall. (Cutting the pipe longer leaves a ¾ inch connection allowance at both ends of the pipe.) Using PVC pipe cement, glue a PVC elbow or coupling fitting to one (1) end of each pipe.

Before inserting the pipe through the wall, mark the other end of the pipe so the elbow orientation can be determined. Also, if a protective shield (refer to Section H., passage 1. of this manual) will be used on the exterior surface of the wall, it should be installed at this time. From the inside, glue a coupling fitting to each pipe, using PVC pipe cement, while being careful to maintain the proper orientation of the termination elbow(s). Complete the assembly of the outlet and inlet as shown in Figure 10, making sure that the spacing between the inlet and outlet complies with that noted in Figure 8.

27

Page 29
Image 29
Thermo Products CMC1-75DV3N, CMC1-50DV3N, CMC1-50D36N, CMC1-75D36N, CMA3-50D36N, CMA3-75D36N Vent Terminal Location Guidelines

FAQ

Why is it important to keep vegetation away from vent and air intake terminations?

Keeping vegetation away from vent and air intake terminations is important to prevent restriction of flue product flow and ensure trouble-free operation of the furnace.

How often should the vent and combustion air terminations be checked for restriction or blockage?

The vent and combustion air terminations should be checked periodically, at least at the start of each heating season, for restriction or blockage from foreign material.

What is the recommended clearance for the outdoor terminals when cutting holes in the outside wall?

The recommended clearance for the outdoor terminals when cutting holes in the outside wall is specified in the manual and should be strictly observed to ensure proper installation.